SPECIFICATIONS

O O u u t t p p u u t t C C o o n n f f i i g g u u r r a a t t i i o o n n
. . . . . . . . . Dual Channel, electrically isolated with
O O u u t t p p u u t t W W a a v v e e f f o o r r m m s s . . . . . . . . . . . . . . AC Mode: Rectangular symmetrical
P P a a t t i i e e n n t t V V o o l l t t a a g g e e . . . . . . . . . . . . . . . . . . . . . . 100 Volts Maximum, No Load
I I n n t t e e n n s s i i t t y y C C o o n n t t r r o o l l . . . Dual intensity potentiometers: 0-25 mA peak current
output, adjustable current. Constant current
regulation from 0 to 4000 ohms load minimum.
P P u u l l s s e e R R a a t t e e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fixed, 80 Hz
P P u u l l s s e e D D u u r r a a t t i i o o n n . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fixed, 300 µSec
P P u u l l s s e e C C h h a a r r g g e e . . . . . . . Maximum of 8 µCoulombs under normal operation
O O u u t t p p u u t t P P r r o o t t e e c c t t i i o o n n . . . . . . Under 15 µCoulombs charge per pulse with any
single component failure.
T T i i m m e e B B a a s s e e . . . . . . . . . . Crystal controlled oscillator operating at 3.58 MHz
P P o o w w e e r r S S o o u u r r c c e e
Two AA (1.5 volt) Alkaline Batteries. ANSI Type
NEDA1604A. Nickel-Metal-Hydride or Nickel-
Cadmium rechargable batteries.
E E l l e e c c t t r r i i c c a a l l T T y y p p e e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type BF
B B a a t t t t e e r r y y L L i i f f e e . . . . . . . . . . . . . . . 24 hrs or until Low Battery indicator blinks
C C i i r r c c u u i i t t D D e e s s i i g g n n . . . . . . . . . . . Microcomputer with no internal adjustments
C C a a l l i i b b r r a a t t i i o o n n . . . . . . . . . . . . . . . . . . . . . . No Calibration Required or Needed
miniature safety connectors.
biphasic with zero net DC.
S S a a f f e e t t y y R R e e c c o o g g n n i i t t i i o o n n
United States: Conforms to UL Std 2601-1
Canada: Certified to CAN/CSA C22.2 No. 601.1
Meets 93/42/EEC Medical Device Directive
IEC/EN 60601-1
V V i i t t a a l l S S t t i i m m W W a a v v e e f f o o r r m m
1000 ohm Load, Amplitude- 25mA, Tolerance ±10%.
100 µs
6 6
VitalStim™ Therapy Unit
300 µs