General Warnings - Beninca HEAD-MBE Manual De Instrucciones

Central de mando
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 16
The electronic control unit HEAD-MBE can be used to control 2 motors with a power not exceeding
350+350W.
a) The wire connections and the operating logic should be in compliance with regulations in force.
b) The cables featuring different voltage should be physically detached, or adequately insulated by an
additional insulation of at least 1 mm.
c) The cables should be further fastened in proximity to the terminals.
d) Check all connections before powering the unit.
e) Check that settings of the Dip-switches are the required ones.
f) The N.C. inputs which are not in use should be short-circuited.
Terminal No.
Function
1-2
Power supply
3-4
Flashing light
5-6-7
Motor 2 (MB)
8-9-10
Motor 1 (MBE)
11-12
24 Vac
13-14
Electric lock
11-15
SCA
16-17
RX 2ch.
18-19
Aerial
20
Pedestrian
21
Step-by-Step
22
STOP
23
PHOT
24
+V
25-26-27
0-24-12
28-29-30
L1-T1-N1
1) Cut-off power supply.
2) Manually release the wings, move them to approx. half-stroke and lock them again.
3) Reset power supply.
4) Send a step-by-step control signal by pressing the button or the remote control key.
5) The wings should start an opening movement. If this is not the case, invert the movement wires of the
motor. (8/10 for motor M1, and 5/7 for motor M2).
6) Adjust Time, Operating Logic and Motor Power.
WARNING! This adjustment affects the safety of the automatic system.
Check that the thrust applied onto the wing complies with regulations in force.
A Faston (T1) connector is provided on the power supply transformer which allows the power adjustment
of the motors on 4 different levels.
By moving the Faston (T1) to 120, power is at minimum, by moving it to 230, power is at maximum.
HEAD-MBE Control Unit

GENERAL WARNINGS

INPUT/OUTPUT FUNCTIONS
Description
Input, 230Vac 50Hz (1-Phase/2-Neutral)
Output, flashing light connection, 230Vac 40W max.
Connection to motor 2 : (5-move/6-Com/7-move)
Connection to motor 1 : (8-move/9-Com/10-move) – delayed in
closing phase. If only one motor is used, connect Motor 1 output
and adjust TRAC to the minimum value.
Output, accessories power supply 24Vac/1A max.
Electric lock connection, 12Vac/0,5A max.
Open gate indicator light connection, 24 Vac/3W max.
Output, second radio channel. N.O. contact, voltage free.
It is enabled with both fixed receiver and expandable two-channel
receiver
Aerial connection, radio receiver card and incorporated radio mod-
ule (18-screen/19-signal).
Input, N.O. pedestrian push-button
Activation is carried out on motor M1 (8-9-10)
Input, N.O. step-by-step push-button
Input, N.C. STOP push-button
Input, safety devices connection, N.C. terminal (e.g. photocells)
Common to all control inputs.
Connection to transformer secondary winding
Connection to transformer primary winding
To check connections:
To adjust the motor power
7