13 Appendix
13.1 Accessories
Table 15:
Accessories
Description
Socket, CN2 series, female, M12x1, 5-pin, A-coded, for IO-Link connection X7I1
Protective cap M12x1
13.2 Address tables
The minimal configuration consists of six valve positions. Due to the design, an expansion of
valve positions to seven is not possible.
Address data 1
Position
14 coil
1
Coil 1 (X.0)
2
Coil 3 (X.2)
3
Coil 5 (X.4)
4
Coil 7 (X.6)
5
Coil 9 (X+1.0)
6
Coil 11 (X+1.2)
Address data 2
Position
14 coil
1
Coil 1 (X.0)
2
Coil 3 (X.2)
3
Coil 5 (X.4)
4
Coil 7 (X.6)
5
Coil 9 (X+1.0)
6
Coil 11 (X+1.2)
7
Coil 13 (X+1.4)
8
Coil 15 (X+1.6)
Address data 3
Position
14 coil
1
Coil 1 (X.0)
2
Coil 3 (X.2)
3
Coil 5 (X.4)
4
Coil 7 (X.6)
5
Coil 9 (X+1.0)
6
Coil 11 (X+1.2)
7
Coil 13 (X+1.4)
8
Coil 15 (X+1.6)
9
Coil 17 (X+2.0)
AVENTICS | AV03/05 with IO-Link | R412018145–BAL–001–AC
12 coil
Coil 2 (X.1)
Coil 4 (X.3)
Coil 6 (X.5)
Coil 8 (X.7)
Coil 10 (X+1.1)
Coil 12 (X+1.3)
12 coil
Coil 2 (X.1)
Coil 4 (X.3)
Coil 6 (X.5)
Coil 8 (X.7)
Coil 10 (X+1.1)
Coil 12 (X+1.3)
Coil 14 (X+1.5)
Coil 16 (X+1.7)
12 coil
Coil 2 (X.1)
Coil 4 (X.3)
Coil 6 (X.5)
Coil 8 (X.7)
Coil 10 (X+1.1)
Coil 12 (X+1.3)
Coil 14 (X+1.5)
Coil 16 (X+1.7)
Coil 18 (X+2.1)
69
Appendix
Part number
8942051602
1823312001