Descargar Imprimir esta página

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35
Problem
Motor makes a humming
sound, but does not function.
Motor stops automatically.
Extraction capacity
insufficient.
Dust or smoke from the outlet
grid and/or indicator blinks or
is not lit.
Machine makes a crackling
sound (= short-circuit).
11

ORDERING SPARE PARTS

For spare parts available for the machine consult the
supplied exploded view.
Address your order to your supplier and always
state the data below:
- product name, supply voltage and serial number
(see the identification plate)
- article number of the particular part
- description
- quantity
0508080010/SFE-HFE/010111/G
Possible cause
Motor uses 2 phases (this only applies
to 3-phase motors).
Motor capacitor defective or not
connected (this only applies to 1-
phase motors)
Wrong direction of motor rotation.
Motor defective.
Inverted direction of rotation of the
motor.
Extraction fan polluted.
Filters clogged or saturated (*).
False air is being sucked (*).
Ioniser and/or collector are saturated
or mounted incorrectly (*) causing
short-circuiting.
No power on filtercell(s).
Poor contacts in the ioniser and/or
collector.
High-voltage transformer defective.
High-voltage PC board defective.
Short-circuit in the ioniser and/or
collector (caused by bent lamellas).
Ioniser and/or collector incorrectly
mounted.
Ioniser and/or collector heavily
polluted.
Ioniser and/or collector not totally dry.
Bent collector lamellas.
Bent or broken ionisation wires.
Metal particles in ioniser and/or
collector.
Solution
Repair the phase connection.
Repair, replace or connect capacitor.
Change direction of rotation.
Repair or replace motor.
Change the direction of rotation.
Celan the extraction fan.
Clean the filters. See chapter 9.
Check or replace the sealing material.
Clean the filters and mount correctly.
See chapter 9.
Press the "reset" button.
Check and repair.
Replace the high-voltage transformer.
Replace the high-voltage PC board.
Check and repair. See chapter 9.
Mount correctly.
Clean the filters. See chapter 9.
Allow thorough drying after cleaning.
See chapter 9.
Repair. See chapter 9.
Replace. See chapter 9.
Clean the filters. See chapter 9.
EN - 16

Publicidad

loading

Este manual también es adecuado para:

Sfe-50Sfe-75Hfe-25Hfe-50