1.
Unpackage
A.
Remove unit from box. Check for any signs of concealed dam-
age, and that all optional equipment has been provided. Contact
Air Innovations immediately if components are missing or/if unit
has been damaged in shipping.
B.
Shipment includes:
- One (1) Fan-coil unit
- One (1) Mounting flange
- One (1) Supply/Return Grille Assembly
- One (1) Condensing unit
- One (1) remote interface controller with 50' control cable
- One (1) Documentation Bag with auxiliary data plate
2. Installing the Fan-Coil
Decide where the unit will be mounted, consider the supply/
return orientation, to ensure the utilities can be connected to the
correct side of the unit. The Ceiling System consists of a Fan-
coil Chassis, a Mounting Flange, and a Diffuser (Fig. 1). The fan
coil unit can be located either above, or below the condensing
unit in height. Keep any height difference to a maximum of
15' (4.57meters).
Mounting The Fan-Coil
A.
Cut an opening in the ceiling 41" long x 14.5" wide 16" on
center joists, or 41" long x 10.5" wide for a 12" on center
joist spacing (Fig. 2).
B.
Install the mounting flange onto the ceiling and secure it to
the joists using 2 1/2" flat head wood
(not provided). Ensure the hinge area of the mounting
flange is opposite the utility connection side of the unit (Fig.
3).
C.
Connect the fan-coil to the hinge of the mounting flange
(Fig. 4), swing the unit up and connect the fan-coil to the
mounting flange using four (4) washers, lock washers, and
nuts (Provided) (Fig. 5).
D.
Connect all the utilities to the fan-coil. See the
Manual for instructions on how to implement the provided
Swage Locks (Page 35).
ATTENTION
E.
After all utilities are connected, fill in any voids or
holes around unit including utility connection area with
insulation.
F.
Attach the diffuser to the mounting bracket using the hinges
on the diffuser and flange and lock the diffuser into place
using the mounting clips (Fig. 6).
3
construction screws