Package contents (Fig. 1)
Product dimensions (Fig. 2)
Product components (Fig. 3)
A
Fitting frame
B
Plug connection
C
Sensor enclosure with lens
D
Designer trim
Setting capabilities via LiveLink app:
– Reach adjustment
– Twilight setting
– Time setting
– Semi/fully automatic
– Constant-lighting control
– Interconnecting several sensors
– Teach mode
– Test mode
– Daytime operation
– IQ mode
– Basic brightness
4. Installation / wiring
A clip-on ceiling adapter or a frame for fitting onto a mounting box is provided
(Fig. 5).
– Wiring diagram (Fig. 6)
– Network plan (Fig. 7)
The wiring leads selected for installation must comply with the regulations laid
down in VDE 0100 (see safety precautions, page 11). For the wiring of the
presence detector, the following applies: Under section 6 of VDE 0100 520, a
multiple-core lead containing both the mains voltage leads and the control leads
(e.g. NYM 5 × 1.5) may be used for the wiring between sensor and LiveLink
box. The lead between the LiveLink box and the sensor must have a minimum
length of 0.5 m and a maximum length of 300 m (for 1.5 mm²). After installing
and switching on, the LiveLink box takes approx. 45 seconds to start. The sensor
then starts to flash once per second during the initialisation cycle (see safety
precautions, page 11).
Using several sensors
Several sensors can be connected in a LiveLink system. In this case, the maxi-
mum number of DALI users must not be exceeded (see technical specifications,
page 13)
"LiveLink Install" app
"LiveLink" app
- 12 -
5. Detection zone
presence
radial
tangential
Reliable presence detection depends largely on the number, quality and arrange-
ment of the lens elements. The IR Micro LiveLink - with its high-resolution sensor
system, including multi-segment pyro sensor - provides reliable, precision detec-
tion over 6 × 6 metres. The square detection zone provides the basis for creating
optimum configurations quickly and easily.

6. Technical specifications

Dimensions (Ø × D)
Ø 80 × 20.5 mm
Power consumption
3 mA / 2-DALI user,
12 - 22.5 V
Sensor technology
Passive infrared
Switching mode
LiveLink box
Detection zone
360° with 90° angle of aperture
(for ceiling lights)
(84 detection beams and 168 detection zones)
Reach
Square detection zone installed at a height of 3 m:
presence detection zone approx. 4 m × 4 m
Motion detector approx. 6 × 6 m
Time setting
From 1  min to 60  min via LiveLink box
Twilight setting
2 - 1000 lux (via LiveLink box)
IP rating
IP20
Temperature range
Ambient temperature -25°C to +55°C
presence
radial
tangential
, no SELV