Technical Data
13. Technical Data
NOTE: The data given on the rating plate
attached to the column of the light apply.
13.1 Dimensions
Designation
Light head
Column
(variants)
Tab. 4: Dimensions.
13.2 Electrical values
Designation
Voltage range
- Light
- Light +
operating unit
Frequency range
light +
operating unit
Power
consumption
Operating unit
Tab. 5: Electrical values.
Value
STZL 12 R:
218 x 136 x 33 mm
STZL 24 (A)(R):
398 x 136 x 33 mm
STZL 36 R:
577 x 136 x 33 mm
400 + 384 + 252 mm
450 + 244 + 252 mm
500 + 484 + 252 mm
Value
24 V DC
100-240 V AC
50/60 Hz
Light:
STZL 12 R: 11 W
STZL 24 (A)(R): 21 W
STZL 36 R: 31 W
Light +
operating unit:
STZL 12 R: 14 W
STZL 24 (A)(R): 24 W
STZL 36 R: 34 W
Power supply unit
13.3 Classifications
Designation
Protection class
Type of protection
Operating mode
Tab. 6: Classifications.
13.4 Symbols
Symbol
Designation
Protection class I
Operation with protective
earth conductor
Protection class II
Operation with protective
insulation
Protection class III
Operation with safety
extra low voltage (SELV)
Suitable for the electro-
statically protected area
(EPA)
EPA
CE conformity mark
Disposal in accordance
with the European WEEE
Directive
Tab. 7: Symbols.
ENG
Value
Light:
III
Light +
operating unit:
STZL 12 R: II
STZL 24 (A)(R): I
STZL 36 R: I
IP 20
Continuous
operation
27