SPECIFICATIONS
Maximum Surge Watts . . . . . . . . . . . . . . . . .5,625 watts
Continuous Wattage Capacity . . . . . . . . . . .4,500 watts
Power Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.0
Rated Maximum Continuous AC Load Current:
At 120 Volts . . . . . . . . . . . . . . . . . . . . . . .37.5 Amps
At 240 Volts . . . . . . . . . . . . . . . . . . . . . . .18.7 Amps
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . .60 Hertz
Fuel Tank Capacity . . . . . . . . . . . . . . . . . . . 7 U.S. gallons
Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . 164 lbs.
GENERAL MAINTENANCE
RECOMMENDATIONS
The Owner/Operator is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the unit
is kept clean and properly stored. NEVER operate a
damaged or defective generator.
Engine Maintenance
See engine owner's manual for instructions.
Maintenance Minder
The maintenance minder displays and records how many
hours your generator has run (up to 9,999.9). It also alerts
you when to change your oil and to service your air filter.
The message "CHG OIL" will flash after the first 20 hours
of unit operation.This is to remind you to replace the
'break-in' oil with regular duty oil.The same message will
again flash after intervals of 100 hours.The maintenance
reminder does not sense that the oil change has occurred -
it merely flashes the message for a two hour period to
permit you to observe the reminder.
Similarly, the message "SVC AIR FILTER" will flash after
intervals of 50 hours to remind you to service or change
the air filter element.
CAUTION!
When working on the generator,
always disconnect spark plug wire from spark plug
and keep it away from spark plug.
PowerBoss 4,500 Watt Contractor Generator
CAUTION!
contact with used motor oil. Used motor oil has
been shown to cause skin cancer in certain
laboratory animals.Thoroughly wash exposed areas
with soap and water.
KEEP OUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.
Generator Maintenance
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.
NOTE: DO NOT use a garden hose to clean generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air slots,
some of the water will be retained in voids and cracks of
the rotor and stator winding insulation.Water and dirt
buildup on the generator internal windings will eventually
decrease the insulation resistance of these windings.
To Clean the Generator
CAUTION!
through the air cooling slots, even if the engine is
not running.
• Use a damp cloth to wipe exterior surfaces clean.
• A soft bristle brush may be used to loosen caked on dirt
or oil.
• A vacuum cleaner may be used to pick up loose dirt and
debris.
• Low pressure air (not to exceed 25 psi) may be used to
blow away dirt. Inspect cooling air slots and opening on
generator.These openings must be kept clean and
unobstructed.