en
28 | KTS 530 / 540 / 570 (KTS 5 Series) | Decommissioning
6.
Decommissioning
6.1
Temporary shutdown
In the event of lengthy periods of non-use:
¶
Disconnect the KTS 530 / 540 / 570 (KTS 5 Series)
from the mains.
6.2
Change of location
¶
If the KTS 530 / 540 / 570 (KTS 5 Series) is passed on,
all the documentation included in the scope of delivery
must be handed over together with the unit.
¶
The KTS 530 / 540 / 570 (KTS 5 Series) is only ever
to be transported in the original or equivalent pack-
aging.
¶
Unplug the electrical connection.
¶
Heed the notes on initial commissioning.
6.3
Disposal and scrapping
1. Disconnect the KTS 530 / 540 / 570 (KTS 5 Series)
from the mains and detach the power cord.
2. Dismantle the KTS 530 / 540 / 570 (KTS 5 Series)
and sort out and dispose of the different materials in
accordance with the applicable regulations.
6.4
Disposal
This KTS 530 / 540 / 570 (KTS 5 Series) is
subject to European guidelines 2012/19/EU
(WEEE).
Old electrical and electronic devices, includ-
ingcables and accessories or batteries must
be disposed of separate to household waste.
¶
Please use the return and collection sys-
tems in place for disposal in your area.
¶
Damage to the environment and
hazards to personal health are pre-
vented by properly disposing of
KTS 530 / 540 / 570 (KTS 5 Series).
|
1 689 989 289
2014-12-04
7.
Technical data
7.1
General data
Property
Operating voltage
Power consumption through vehicle bat-
tery or power supply
Dimensions (L x W x H)
Weight (without connecting cables)
Degree of protection
Operating temperature
Storage Temperature
Relative operating humidity
7.2
Interface protocols
The following interfaces with respective protocols are
supported for controller diagnosis in conformance with
ISO 15031:
R
ISO 9141-2 (Communications lines K and L)
R
SAE J1850VPW and SAE J1850PWM
(Communication lines BUS+ and BUS-)
R
CAN ISO 11898 ISO 15765-4 (OBD)
(Communication lines CAN-H and CAN-L)
R
CAN Single Wire
R
CAN Low Speed
7.3
Multimeter specifications
Measuring channel 1 (CH1)
Measuring channel 2 (CH2)
Input resistance > 900 kOhm.
7.3.1
DC measurement (CH1 and CH2)
!
Use measuring leads for measurements smaller than
60 VDC, 30 VAC or 42 VACpeak only.
Property
Value/Range
Measurement range 200 mV — 60 V
Precision CH1
±0.75 % of measurement value,
additional ±0.25 % of measurement range
Precision CH2
±2 % of measurement value,
additional ±0.5 % of measurement range
Resolution
100 µV — 100 mV
(depending on measuring range)
Value/Range
7 VDC — 30 VDC
approx. 6 Watt
170 x 120 x 40 mm
325 g
IP 20
5 °C – 40 °C
41 °F – 104 °F
-25 °C – 60 °C
-13 °F – 140 °F
90 % non-
condensing
zero potential
potential based