PROTECTION FUSES
Position
Value
F1
6 A
315 mA
F2
PROGRAMMING PROCEDURE AND SYSTEM CONFIGURATION
The system adjustments can be accessed via the display. There are 4 different menus marked with the letters A,
C, F and H.
Closing limit switch input - motor 2 (N.C.).
FCCM2
If not used, disable during programming by enabling the C10 menu.
PHOTOCELL 2 input (N.C.).
If not used, jumper with terminal 31
Operation:
Input active during both opening and closing.
If intercepted, it immediately stops the motion and holds it stopped until the photocell
PH2
is freed. Upon release, motion always restarts in opening.
If intercepted when the gate is closed, following a Start command, it does not allow
opening the gate and it will be signalled with 5 fast flashes. Upon release, the gate
will start opening without having to give further commands.
If intercepted during pause, it reloads the pause time.
Not used
SAFETY DEVICE input (N.C.).
If not used, jumper with terminal 31
Operation:
FRAME
Input active both during opening and closing.
Stops the motion and inverts it for 2 seconds. The gate will remain locked until the
next Start pulse, which will restart it in the obstacle freeing direction.
Not used
PHOTOCELL 1 input (N.C.).
If not used, jumper with terminal 31
Operation:
Input active only during closing.
PH1
Stops the motion and inverts it, fully opening the gate.
When the gate is closed, it is uninfluential.
If intercepted during pause, it reloads the pause time.
COM
COMMON INPUTS/OUTPUTS.
ANTENNA GROUND input.
GND
ANTENNA SIGNAL input.
ANT
Connector for plug-in radio receiver.
Description
Type
FAST
Motor protection and primary transformer.
Low-voltage protection and accessories.
FAST
BA230