Descargar Imprimir esta página

Important - Novellini Glax R90 p.80 Manual De Instalación, Uso Y Mantenimiento

Publicidad

PRODUCT GUARANTEE:
The product is guaranteed as per Italian Presidential Decree
224 of 24/05/1988 in Italy and the rest of the EU and as per
CEE Directive 85/374 in terms of product liability.
The
Manufacturer
guarantees
its
manufacturing and material defects – provided these are
confirmed by the authorised personnel of the Company – for
a period of 24 months from the purchase date, as indicated
by the receipt or invoice.
The guarantee covers repairs to and/or replacement of the
parts considered to be faulty. The guarantee does not cover
complete replacement of the product. The guarantee does
not cover the lights, warning lights, fuses, glass parts, mirrors
and decoration parts unless these are faulty due to production
defects and not due to neglect or improper use. The
guarantee does not cover any parts and components which
are faulty or damaged due to negligence or carelessness
during use, incorrect installation or maintenance, operations
carried out by non-authorised personnel, damage caused
during transport or any other circumstances not due to
product manufacturing defects, such as sudden electricity
jolts, lightning, electrolysis, corrosion and, in general, any
causes related to the nature of the water and electrical and
water supply systems in the place where the unit is used.
The Purchaser must check that the product is not damaged
in any way before installation and must contact the agent
or authorised assistance centre immediately if any faults are
detected. The guarantee will only be applied on presentation
of a document indicating the purchase date.
In the event of operations without proven defects or to
illustrate how to use the product, all the expenses are
sustained by the Purchaser. Any repairs or modifications
carried out by personnel not authorised by the Manufacturer
will not be covered by the guarantee and will render the
remaining guarantee period immediately null and void.
The Manufacturer is not responsible in any way for any direct
or indirect damage caused to persons, animals or things due
to failure to comply with all the regulations in the installation,
instruction and maintenance manual supplied with the
product.
Any disputes will be dealt with exclusively by Mantova Italy,
Law Court.
This symbol indicates important product instructions
or important safety information.

IMPORTANT:

Before you start to assemble and install the product, carefully
read through all the instructions. Unpack the components
and check that nothing is missing and that there are no
damaged or faulty components, remove the transparent
protective film. Before you install the shower cubicle in its
final position, perform a test run. Run the unit for several
minutes and check for water leaks and any damage caused
during transport and handling. This product should be
installed by suitably skilled personnel.
N.B.: This product is designed for installation on finished walls
and floors.
Warranty claims must be produced with the purchase invoice
and the product assembling instructions.
The drawings and illustrations in this manual are provided for
information purposes only.
The manufacturer reserves the right to make changes and
improvements without prior notice.
WARNING!
If water hardness is above 14°f a water softener will have to be
installed. Chlorine content must not exceed 100 mg per litre.
In the event of the instructions in this notice not being
followed, the warranty shall be invalidated.
Electrical connection:
Novellini S.p.a. hereby certifies that the product conforms
to current health and safety regulations at the time of sale
and that the product has the CE-mark and Declaration of
Conformity. All products and components are tested during
manufacture in accordance with the relevant reference
standards and company quality system procedures. In order
to ensure that your Novellini product maintains these high
standards after installation and throughout its service life,
please read the following instructions.
1) Check that the mains electrical equipment connected
to cubicle conforms to current electrical standards
and regulations and is fitted with a fully efficient earth
connection.
2) Current electrical regulations forbid the installation of any
electrical equipment (e.g. plugs, switches) inside a radius of
products
against
60 cm from the cubicle and at a height of 225 cm.
3) Check that rating of the mains power supply line matches
the absorbed power specified for the cubicle (see Technical
specifications).
4) The electrical connection between the cubicle and the
mains must be protected against water spray and must
have a protection rating of IP55 or higher.
5) The electrical equipment upstream from the cubicle
must be fitted with an omnipolare 30 mA switched circuit
breaker with a minimum contact opening of 3 mm, which
conforms to current electrical regulations.
6) Novellini S.p.a. declines all responsibility for injury
or damage resulting from failure to observe these
instructions.
~
Dismantling the shower valves:
In the event of the formation of lime scale and a resulting
malfunctioning of the shower valves, dismantle the parts
(fig. A/B/C...). We recommend you immerse the cartridge in
normal vinegar until it is completely lime scale-free.
To ensure correct operation of the thermostatic mixer,
the unit must be supplied from a boiler or a water heater
providing 6 to 7 litres per minute of water at a temperature
of 60/65°C.
INSTRUCTIONS FOR USE:
electrocution Hazard. Do not use electrical equipment of
any type inside the shower enclosure when the shower is
operating.
Massage functions:
CASCADE.
FIXED SHOWER HEAD.
HYDRO-NECK.
HYDRO-BODY: for a total body massage concentrating on
the spinal column. Relieves back pain, tiredness and muscular
aches. Ideal for reducing physical stress.
PRECAUTIONS:
Integrated cubicles will provide a variety of benefits if used
properly. You should observe the following precautions.
1) Do not exceed a maximum water temperature of 45°C.
2) Do not use the shower or the steam bath after a heavy
meal and while you are still digesting.
3) Do not exceed the maximum load of the seat (120 kg).
4) Children and the infirm should only use the cubicle under
the supervision of an adult.
5) Do not use the steam bath for longer than 20 to 30
minutes. Maximum permitted steam bath times vary with
age and body weight.
6) Persons with serious heart problems, high blood pressure
and acute illnesses should consult a medical practitioner
before using the steam bath.
7) SCALDING HAZARD. During a steam bath, keep your feet
away from the steam outlet nozzle.
CLEANING THE SHOWER UNIT:
CARING FOR YOUR CUBICLE
The cubicle panels are made with acrylic parts and must be
cleaned using a liquid detergent and a soft cloth or sponge.
Use a good quality household liquid detergent. To prevent
scale deposits, wipe dry using a chammy leather or a soft lint-
free cloth that removes stubborn deposits without leaving
traces. Limescale deposits may be removed using specific
detergent products. To restore shine to the acrylic surface
polish with an ordinary wax polish such as car wax. DO NOT
USE ABRASIVE CLEANERS, ALCOHOL OR ALCOHOL BASED
PRODUCTS, ACETONE OR OTHER SOLVENTS.
TROUBLESHOOTING:
Before calling the Service Centre, check that:
• The hoses are properly connected and not kinked.
• Hot and cold water is being correctly delivered to the wall
fittings.
• The water supply system was bled before the shower unit
600 mm
was installed.
1
2400 mm
• The mains power supply is reaching the steam generator
2
and the green Power On LED on the control panel is lit.
3
If you have followed the instructions and the shower still
(I)
does not work, call the nearest Service Centre. The telephone
numbers of authorised service centres are given in the
enclosed list.
WASTE DISPOSAL:
To dispose of the shower unit or any part of it, follow local
waste disposal regulations. In Italy, Legislative Decree No. 22
of 5 February 1997 applies. In other EU countries, the subject
is governed by directives 91/156/EEC, 91/689/EEC and 94/62/
EC.
49
Liquid soap
WARNING: it could be dangerous for
No
pace-maker wearer.
pacemakers
Romanore di Borgoforte, lì 01.10.2007
Novellini S.p.a.
Gianfranco Novellini
Amministratore delegato
ENGLISH

Publicidad

loading