AC supply:
90 ... 260 V AC / max. 8 VA
50/ 60 Hz
ext. fuse protection: T 0.1 A
DC supply:
10 ... 30 V DC/ max. 1.5 W
reverse polarity protection
ext. fuse protection T 0.2 A
24 V DC ±15%, 80 mA
AC supply:
DC supply:
max. 80 mA, external voltage
supply is connected through
Operating temperature: -20°C .. +65°C
Storage temperature:
Relative humidity: RH. 93% at +40°C,
Altitude:
Noise immunity:
EN61000-6-2
with shielded signal and
control cables
Noise emission:
EN55011 Class B
Design to:
EN61010 Part 1
Protection Class:
Class 2
Application area:
Soiling Level 2
Housing:
Panel-mount housing
to DIN 43 700, RAL 7021
Dimensions:
48 x 48 x 91 mm
Panel cut-out:
45
Installation depth:
ca. 107 mm incl. terminals
Weight:
ca. 125 g
Protection:
IP 65 (front)
Housing material:
Polycarbonate UL94 V-2
Vibration resistance: 10 - 55 Hz / 1 mm / XYZ
(EN60068-2-6):
30 min in each direction
Shock resistance
100G / XYZ
(EN60068-2-27):
3 times in each direction
Cleaning:
The front of the unit should
only be cleaned using a soft
damp (water!) cloth.
Supply voltage and outputs:
Plug-in screw terminal, 7-pin, RM5.08
Core cross section, max. 2.5 mm²
Plug-in screw terminal, 5-pin, RM 3.81
Core cross-section, max. 1.5 mm²
Signal and control inputs:
Plug-in screw terminal, 8-pin, RM 3.81
Core cross-section, max. 1.5 mm²
www.kuebler.com
-25°C .. +75°C
non-condensing
to 2000 m
+0,6
+0,6
x 45
mm
Preset counter
Mounting clip
Instruction manual
6.924.X10X.XXC
2 additional relay outputs
Input trigger levels
Supply voltage
LCD version
Outputs
Front
0 = Standard (HTL)
A = Fixed level
0 = 90 .. 260 VAC
3 = 10 .. 30 VDC
0 = no backlighting
1 = green backlighting
2 = LED Look
3 = Multicolour
0 = Relays
0 = Kübler version
A = Neutral version
*Fixed level (Low 0 ... 2 V DC,
High 3,5 ... 30 V DC)
Seite 18