5.3.1. Setting the time of the day (TD)
Set the time in the system.
A
Press and hold
the parameter display reads TD.
B
Set the time with
C
Press
to validate the selection and return to the service mode, or wait for 10
seconds.
5.3.2. Days Override (DO)
Set the maximum number of days of operation without regeneration according to local regulation.
A
Press
and
B
Select the number of days of Override with
C
Press
to validate the selection and advance to the next parameter.
5.3.3. Regeneration time (RT)
Set the time of regeneration at a time of low or no water usage.
D
Adjust the regeneration time with
E
Press
to validate the selection and advance to the next parameter.
5.3.4. Feed Water Hardness (H)
Set the feed water hardness in °TH.
F
Adjust the feed water hardness with
G
Press
to validate the selection and advance to the next parameter.
5.3.5. Safety factor (SF)
Set the safety factor in %.
NOTE
The safety factor value, expressed in percentage, will be added to the calculated reserve if cr option
is selected in RS. It could be a fixed percentage of total volume if RS SF option is selected.
H
Adjust the safety factor with
I
Press
to validate the selection and get out of basic programming mode.
6 .
Startup
1.
Fill the brine tank in the cabinet with salt.
2.
Adjust the safety brine valve in the brine well to make sure the overflow elbow is installed above the float level.
3.
After the softener has been running a few minutes in service, proceed to hardness test on outlet water to make sure the
water is treated as per requirements, and eventually adjust the mixing device accordingly.
NOTE
Pentair advise to set a residual hardness between 50 and 100 mg/L of CaC0