Commissioning/start-up
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
· Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
· Isolate the device (disconnect from the power supply) before carrying out any work on it.
Prerequisite
· First switch on the pump, then the UVC clarifier.
· Check all connections for leaks.
Switching ON/switching OFF
· Switching on: Insert the power plug into the socket.
– The unit switches on immediately.
· Switching off: Disconnect the power plug.
Check the function.
Vitronic 11 W
5 F
· The function display is lit when the UVC lamp is switched on.
Vitronic 18 W / 24 W / 36 W / 55 W
5 G
· The function display is lit when the UVC lamp is switched on.
· The transparent stepped hose adapters are lit when the UVC lamp is switched on.

Remedy of faults

Malfunction
The performance of the unit is not satisfactory
UVC lamp is not lit

Maintenance and cleaning

W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
· Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
· Isolate the device (disconnect from the power supply) before carrying out any work on it.
Cleaning the device
Recommendation regarding cleaning:
· Do not use aggressive cleaning agents or chemical solutions as they could attack the housing or impair the function
of the unit.
· Recommended cleaning agent for removing stubborn limescale deposits:
– Pump cleaning agent PumpClean from OASE.
– Vinegar- and chlorine-free household cleaning agent.
· After cleaning, thoroughly rinse all parts in clean water.
16
Cause
The water is extremely soiled
The quartz glass is soiled
The UVC lamp capacity is exhausted
Flow rate is too high
Power plug not connected
UVC lamp defective
Connection defective
UVC overheated
Remedy
Remove algae and leaves from the pond,
change the water
Clean the quartz glass
The lamp must be replaced after 8000 operat-
ing hours
Reduce the pump output
Connect power plug
Replace the UVC lamp
Check electrical connection
Vitronic 55: UVC automatically switches on
when it has cooled down