Section 6
Page 24
6
Troubleshooting and Repair
6.1
Safety Measures
DANGER
WARNING
CAUTION
6.2
Instructions regarding Fault Repair
Please check first whether there is an operating fault. You can repair some faults yourself.
Servicing may be carried out by authorised specialists only. Indicate the information given on the rating plate
if you contact the after-sales service or order spare parts.
Only use original spare parts to replace defective components.
Regular inspection and maintenance of the appliance prevent disruptions to operations and ensure safety.
Inspection and maintenance intervals depend on the use of the appliance. Consult your dealer's after-sales
service department.
6.3
Fault and Action Table
Fault
Appliance does not become warm;
indicator light does not come on.
Appliance does not become warm;
indicator light does not come on.
Appliance does not become warm;
indicator light does not come on.
Appliance does not become warm;
indicator light is on.
Powerstapler
PSUH
Hazardous electrical voltage
Electrical current can pose a considerable threat to life and physical well-
being and may lead to injuries.
Switch off the appliance at the mains before performing troubleshooting. Pull
out the mains plug and insert it into the plug park provided.
Hazard caused by hot surfaces
The internal surfaces of a heated appliance and the base plates can become
hot during operation and only cool down slowly in the air.
In the event of a malfunction, allow the appliance to cool down with the cover
removed; wear suitable protective gloves.
Exposed springs
If the stacking platform is pressed down by hand, the springs are exposed.
Reaching into the gaps of the exposed springs may cause hand injuries.
Never press the stacking platform down by hand.
Be careful when attaching and detaching the springs. Pay particular attention
to the ends of the tension springs when adjusting springs on sharp edges.
Possible cause
Defective building fuses.
Defective on/off switch.
Defective connecting lead or mains
plug
Defective circuit, thermostat or heating.
Troubleshooting and Repair
Safety Measures
Remedy
Check fuse and repair if necessary.
Disconnect the appliances from the
mains and have it checked and re-
paired by authorised technical staff if
necessary.
Disconnect the appliances from the
mains and have it checked and re-
paired by authorised technical staff if
necessary.
Take the appliance out of operation
and have it checked and repaired by
authorised technical staff if neces-
sary.
91346811_A1