MOUNTING AND INSTALLATION

3.3

Data plate description

The data plate certifi es the country where the product is
intended to be installed.
The data plate contains the following data:
Abreviation/
Description
symbol
Country where the product is
Country code: "GB"
intended to be installed
Commercial name of the product and
Serial-no
its serial
number
Code
Product code of the appliance
PMS
Central heating maximum pressure
V/Hz
Electrical voltage / frequency
A
Current
W
Maximum electrical consumption
IP
Electric protection index
See chapter "CE Mark"
See chapter "Recycling and
disposal"
4
Mounting and installation
i
Notes
All the drawings dimensions are shown in mm.
4.1

Preparing the mounting and installation

4.1.1
Delivery and installation on site
4.1.1.1
[product] unpack
► Remove the product from its box.
► Remove the protective fi lm from all parts of the product.
4.1.1.2
Check scope of delivery
► Please check the scope of delivery for completeness.
- 1 Hydraulic module
- 1 bag of accessories
- Attachment bracket (x1)
- Flat gasket 1" (x6)
- Flat gasket 1"1/4 (x2)
- 1 bag of documents (1 operating and installation)
18
4.1.2
Observing distances and mounting
clearances
4.1.2.1
Product and connection dimensions
3 6
0
180
81.5
4.1.2.2
Distance to infl ammable parts
► Make sure that no item that can easily catch fi re is in
direct contact with the components, which may reach a
temperature greater than 80°C.
► Make sure that there is a minimum distance of 200 mm
between items that can easily catch fi re and the hot
surfaces.
0
2 5
180
87
101
40
40
81.5
0020166669_04 - 03/15 - Vaillant