Tools Required - Eaton NFFLD-L Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Instructions - NFFLD-L/UFLD-L
INSTALLATION
Trunnion Mounting (Figure 1.)

Tools Required

Torque wrench (ft-lbs), torque wrench (in-lbs), 3/4" socket
and 7/16" socket.
1.
Mount luminaire to surface using the hole pattern
provided on the trunnion bracket.
Hardware recommended: 1/2" diameter bolt x 1-1/2"
N
ote:
long. (Supplied by others)
2.
Loosen but do not remove (2) center bolts and (1) set
screw. (Figure 1.)
3.
Rotate luminaire to desired aiming position and tighten
center bolts to 75 ft-lbs.
4.
Tighten set screw to 30 in-lbs.
5.
Refer to wiring diagrams for power connection.
(Figure 4.)
Trunnion Bracket
3-13/16"
(97mm)
9-5/16"
7/8" (23mm)
(237mm)
Figure 1.
2
EATON
IB506004EN
Set
Screw
Center Bolt
2-5/16"
(59mm)
(2) 9/16"
(15mm)
Installation instructions
Slipfitter Mounting (Figure 2.)
Tools Required
Torque wrench (ft-lbs), torque wrench (in-lbs), 3/4" socket,
3/8" allen drive, #2 phillips head screw driver and
3/8" square nut driver.
1.
If angle adjustment is required please proceed to
step 2, if not skip to step 5.
2.
Remove (3) cover plate screws and cover plate with #2
Philips screwdriver. (Figure 2.)
3.
To change luminaire tilt angle, loosen center bolt, rotate
fixture to the desired angle, and tighten center bolt to
30 ft-lbs.
4.
Replace cover plate and tighten cover plate screws with
#2 Philips screwdriver to 15 in-lbs.
5.
Make wiring connections per wiring diagram and place
connections into pole or mounting bracket. (Figure 4.)
6.
Loosen (4) set screws and slide the slipfitter onto pole
or mounting bracket.
7 .
Position luminaire into the desired direction and tighten
(4) set screws to 10 ft-lbs. (Figure 2.)
8.
Tighten lock nuts to 15 ft-lbs. (Figure 2.)
Cover Plate
Screws (3)
Cover Plate
Lock Nuts (4)
Pole
Figure 2.
Center Bolt
Set Screws (4)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ufld-l

Tabla de contenido