Pkx Series Metering Pumps; Operation - ETATRON D.S. PKX MA/A Serie Normas De Instalación, Uso Y Manutención

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

2.0 - PKX SERIES METERING PUMPS

2.1 - OPERATION

The metering pump is activated by a teflon diaphragm mounted on a piston of an electromagnet.
When the piston of the electromagnet is attracted, a pressure is produced in the pump body with an expulsion
of liquid from the discharge valve. After each pump pulse is finished a spring brings the piston back to the
initial position, with a recall of liquid through the suction valve.
The operation is simple the pump does not need lubrication, therefore maintenance is reduced almost to zero.
The materials used for the construction of the pump make it particularly suitable for aggressive liquids.
The metering pump has been designed to feed liquids with capacities from 0 to 20 l/h and pressures from 0 to
15 bar (depending on the model selected).
2.2 - MAIN FEATURES
The products are manufactured according
Anti-acid plastic casing.
Control panel protection assured by an adhesive polyester film, weatherproof and resisting UV rays
Standard power supply (fluctuations not to exceed ±10%):
230 V a.c.50 Hz single phase.
Optional power supply (fluctuations not to exceed ±10%):
240 V a.c.50-60 Hz single phase;
110 V a.c. 50-60 Hz single phase.
Overvoltage cat. II.
Environmental Conditions: IP65 protection, altitude up to 2000m, ambient temperature 5C to 40C, maximum
relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.
Pollution degree 2
OVERALL DIMENSIONS (
regulation.
14
Fig. 1)

Publicidad