17
16
3
COM
15
COM
4
STOP
COM.
5
OPEN
COM.
6
CLOSE
COM.
7
PHOTO.
+
24 Vdc
-
8
3W Max
+
9
BLINKER

4. Signalling led

"Power On": lighted when the control unit is powered.
"Edge": lighted if the safety edge contact is closed.
5.
Preliminary checks
Preliminary checks must be executed by qualified personnel only, paying the maximum attention . The correct wiring of the motor is very im-
portant for a correct functioning of the automation.
After having checked the wirings and verified that there are
no short circuits, unlock the motor and power the system.
1
Press the cabled button open.
2
Press the cable button close.
3
6-1622605
rev.0
07/05/2013
Connect the neutral of the motor to the
clamp 15 of the control unit.
Connect the phase "1" of the motor to the
clamp 16 of the control unit.
Connect the phase "2" of the motor to the
clamp 17 of the control unit.
Connect the contact NORMALLY CLOSED
2
contact of the STOP between the clamp 1
and 2 of the terminal board.
WARNING: jumper the input 1 to the input
1
2 if not used.
Connect the button OPEN between the
2
clamp 2 and 3 of the terminal board. Leave
it open if not used.
3
Connect the button CLOSE
2
clamp 2 and 4 of the control unit. Leave it
open if not used.
4
Connect the NORMALLY CLOSED contact
2
2
of the photocell (PHOTO) between the clamp
2 and 5 of the terminal board.
WARNING: jumper the input 2 to the input
5
5
5 it not used.
Connect the clamp 8 of the control unit to
the clamp " + " of the power supply of the
transmitter of the photocells.
Connect the clamp 7 of the control unit to
8
the clamp" - " of the power supply of the
7
receiver and transmitter of the photocells.
Connect the clamp 6 of the control unit to
6
the clamp " + " of the power supply of the
photocells receiver.
11
Connect an eventual blinker with self-blinking
circuit between clamps L 11 (line in) and N
15 (common of the motor).
15
ITA
ENG
Check that the motor wiring is compliant with the
installation. To do this, follow the procedure of the
preliminary checks
If the STOP input is open, then this causes the
immediate stop of the automation.
The activation of the OPEN button gives an opening
impulse to the automation.
between the
The activation of the CLOSE button gives a closing
impulse to the automation.
The PHOTOCELL (PHOTO) can cause the STOP
of the automation or the motion inversion .
See chap.9
WARNINGS: the control unit gives a voltage of 24
Vdc.
The output activates at the same time of the motor.
Use a blinker with self-blinking circuit.
"Photo": lighted if the photocell contact is closed.
"Stop": lighted if the stop contact is closed.
Check the status of the signalling LED "edge", "photo",
"stop" considering that all the inputs normally closed must
have the correspondent led lighted.
The automation opens. Correct functioning.
The automation closes, inverse the connections between
the clamp 16 and 17.
The automation closes. Correct functioning.
The automation opens, inverse the connections between
the clamp 16 and 17.