10. USE AND CARE

Grease filters and bottom panel.
The grease filters and the bottom panel should be cleaned frequently. Use a warm detergent solution.
Remove grease filters by pushing them towards the back of hood and rotating downward.
Clean all-metal filters in the diswasher using a non-phophate detergent. Discoloration of the filter may occur if using
phosphate detergents, or as a result of local water conditions — but this will not affect filter performance. This discoloration
is not covered by the warranty.
S
: H
TAINLESS STEEL CLEANING
Do: - Regularly wash surfaces with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent.
- Always clean in the direction of original polish lines.
- Always rinse well with clear water (2 or 3 times) after cleaning. Wipe completely dry.
- You may also use a specialized household stainless steel cleaner.
Don't: - Use any steel or stainless steel wool or any other scrapers to remove stubborn dirt.
- Use any harsh or abrasive cleansers.
- Allow dirt to accumulate.
- Let plaster dust or any construction residues reach the hood. During construction or renovation, cover the
hood to make sure no dust adheres to stainless steel surface.
Avoid: when choosing a detergent
- Any cleaners that contain bleach will attack stainless steel.
- Any products containing : chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
- Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive
and should never be used close to a range.
E
:
NAMEL FINISH
Clean with warm water and mild detergent only. If discoloration occurs, use a good enamel polish such as automotive
polish. (DO NOT use rough abrasive cleaner or porcelain cleaner).

11. WIRING DIAGRAM

Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with
all applicable codes and standards. Before connecting wires, switch power off at service panel and
lock service disconnecting means to prevent power from being switched on accidentally.
Line 120 V
Supply
BK
BK
Neutral
W
W
Light Socket
Ground
W
W
W
BL
FAN MOTOR
WIRING COLOR CODE
BK
BLACK
BL
BLUE
BN
BROWN
G
GREEN
O
ORANGE
HE0042A
"BRIGHT LOOK"
OW TO MAINTAIN ITS
!
W
50 W max.
Y
Y
Light Socket
50 W max.
BN
BK
BK
BK
G
nc
nc
R [70]
P [50]
BL [35]
W
W
O [0]
P
PURPLE
R
RED
W
WHITE
Y
YELLOW
nc
no connection
WARNING
J5
3
BK
2
nc
1
W
J6
3
Y
2
BK
1
nc
J4
BK
4
Y [120]
R
3
2
P
BL
1
nc
ELECTRONIC
ASSEMBLY
A1
Main power board
ELECTRONIC
ASSEMBLY
A2
User Interface
1. If any of the original wire, as supplied, must be replaced, use the
same equivalent wire.
2. Field wiring must comply with applicable codes, ordinances and
regulations.