Descargar Imprimir esta página

After Use; Motor Brushes - Nilfisk-Advance Advolution 20 Instrucciones Para El Uso Y Lista De Piezas

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
ENGLISH

AFTER USE

1
Lift the Operator Handle (6) until it locks in the upright position. NOTE:
The Safety Lock Button (2) will not depress unless the Operator Handle
(6) has been released and tilted back into the operating position. This
will prevent the motor from being engaged while Operator Handle (6) is
in the storage position.
2
Unplug the Power Cord (5) and wrap it around the Handle Release Latch
(4) and the right Operator Handle Grip (1).
3
Check the skirt around the dust control housing. The skirt should be
replaced if it is worn out or torn.
4
Remove the pad from the machine. Clean the pad and hang it up to dry.
Allow buffing pads to dry completely before using again.
5
Wipe the entire machine with a clean, damp cloth.
6
Inspect the entire machine and all accessories for damage. Perform any
required maintenance or repairs before storage.
7
Store the machine in a clean, dry place with the Operator Handle (6)
locked in the upright position.
MAINTENANCE
C - DUST COLLECTION BAG
The dust collection bag should be removed and replaced after about every 20
hours of use. Tip the machine back onto it's handle (6), the same as you would
if you were changing the pad. Squeeze in on the sides of the bag cover "A" and
remove it from the machine. Remove the dust bag "B" (being careful not to spill
any debris) and discard. Tip the machine back upright. Push in on the sides of
the new bag "B" to pop-it-open and install it by pushing it down (grip the cardboard
base of the bag) onto the (2) tubes protruding from the base. Re-install the cover
"A".

MOTOR BRUSHES

This machine is equipped with a motor brush wear indicator light. If this light
comes on during use, contact your local Nilfisk-Advance distributor to have the
motor serviced.
NOTE: If the supply cord is damaged, it must be replaced by the manufacturer
or its service agent or a similarly qualified person in order to avoid a hazard.
6 - FORM NO. 71279A - Advolution 20, 20XP
CAUTION!
The motor can be severely damaged if the machine is used for
an extended period of time with the light glowing.
TROUBLESHOOTING
SWIRL MARKS
Floor not clean.
Area not properly swept - debris in pad or brush.
Improper pad for the job.
Moving the machine too fast.
CIRCLES ON THE FLOOR
Machine standing still while the pad is running.
FLOOR FINISH REMOVED
Improper pad...too aggressive.
Moving the machine too slowly.
MACHINE VIBRATES DURING OPERATION
Defective pad... one side is more dense than the other.
Machine left sitting on pad for extended period of time causing pad
to "take a set".
Pad not "seated" properly into pad holder bristles..
Pad not centered on pad holder periphery.
Pad not rated for RPM of high speed burnisher.
Defective pad driver. Remove pad, hold machine up off of floor with
handle and start machine. If machine vibrates, replace pad driver.
MACHINE DOES NOT RUN
Check plug for proper connection - on machine and at wall outlet.
Check building circuit breaker.
Call for service.

Publicidad