5.8 Outward opening installation
A
Opening
(mm)
90°
130
Weld the extra bracket to that of the pillar, secure the extra
bracket to the pillar making sure the A and B quotas are
met as shown in the table.
Open the gate to a 90° arc, weld or secure using proper
screws the gate bracket making sure the E quota is met.
Secure the gearmotor to the brackets.
Connect the gearmotors to the panel as shown in the diagram.
Power
230V a.c.
50/60 Hz
B
E
(mm)
(mm)
130
720
Gate bracket
Pillar bracket
Extra bracket
Delayed
closing
action
Extra bracket
Delayed
opening
action