Ribind K 2007 Manual De Instrucciones página 24

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

G
B
during the deceleration by turning the appropriate trimmer LOW sPEED.
6 - Press and hold the PROG button to close completely the gate. Turn DIP1 to
OFF, the RED led DL1 will stop blinking.
During Point C procedure, safety devices (photocells and safety strip) are
not active.
(#) In Point D and Point E procedures, all the safety devices (photocells and safety
strip) will be active, so they must be properly installed and connected to the control
board. Any changing of the safety devices input state, will stop the Point D and
Point E procedure that must be repeated from the beginning.
POINT D
- PrOGrAMMING (#)
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, LED DL1 starts blinking
3 - Press PrOG. Button, motor opens.
4 - Once reached the open position, the open limit switch will cut out motor and the
gate travelling will be stored. The gap of time between now (stop of motor) and
the next pressing of the PROG. button (see step 5 below) will be then stored as
waiting time for Automatic Closing feature.
5 - Press PrOG. button, gate closes and the Automatic Closing time is stored (see
DIP3 function to enable or disable the Automatic Closing feature).
6 - The LED DL1 will turn OFF, signalling exit from the Point D procedure.
Closing of the gate will be carried out at normal speed and only on approaching
total closing at low speed (depending on the adjustment of LOW SPEED
trimmer).
7 - When the gate leaf reaches the close limit switch plate, the motor stops.
8 - Turn DIP2 to Off position.
During Point D procedure, safety devices (photocells and safety strip) are
active.
POINT E
- PrOGrAMMING Of PEDEsTrIAN OPENING (#)
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, the LED DL1 starts blinking quickly
3 - Immediately, turn also DIP1 to ON position, the LED DL1 starts blinking slowly
4 - Press the pedestrian pushbutton PED. BUTT, the gate opens
5 - When the gate leaf is opened enough for the pedestrian crossing, press the
pedestrian pushbutton PED. BUTT to stop the travel (thus defining the
opening stroke of the motor). The gap of time between now (stop of the motor)
and the next pressing of the PROG. button (see point 6 below) will be stored as
waiting time for Pedestrian Automatic Closing feature.
6 - Press the pedestrian pushbutton PED. BUTT, gate closes and the Pedestrian
Automatic Closing time is stored (see DIP3 function to enable or disable the
Automatic Closing feature).
7 - Turn DIP1 to Off position.
8 - Turn DIP2 to Off position.
During Point E procedure, the safety devices (photocells and safety strip)
are active.
POINT f
- PrOGrAMMING rADIO CODEs fOr COMPLETE
OPENING
(UP TO 30 CODEs - ONLY fOr CrX MODELs)
You can only programme the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 2 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each,
for 10 seconds.
3 - Press the remote control button (normally channel A) within the 10 seconds
proscribed. If the remote control has been correctly programmed, the DL2 LED
(green) will flash once.
4 - The code programming time resets automatically so that you can programme
the next remote control.
5 - To finish programming, let 10 seconds pass and then press the PROG. button
briefly. The red DL1 LED will stop flashing.
6 - Reposition DIP 1 to OFF and DIP 2 to OFF.
7 - You have completed the procedure
PrOCEDUrE fOr DELETING ALL rADIO CODEs UsED ONLY fOr
COMPLETE OPENING
You can only delete the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 2 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each,
for 10 seconds.
3 - Press and hold the PROG button for 5 seconds. The green DL2 LED will flash
twice to confirm that the stored codes have been deleted.
4 - The red programming DL1 LED remains active and you can programme new
codes as shown above if required.
5 - Reposition DIP 1 to OFF and DIP 2 to OFF.
6 - You have completed the procedure.
HOW TO CHECK If THE MEMOrY Is fULL fOr rADIO CODEs UsED ONLY
fOr COMPLETE OPENING
You can only check the memory if the gate is closed.
1 - Position DIP 1 to ON and then DIP 2 to ON.
2 - The green DL2 LED will flash 6 times if the memory is full (30 codes have been
stored).
3 - After this, the DL1 programming LED will remain active for 10 seconds, so that
you can delete all codes if required.
4 - Reposition DIP 1 to OFF and DIP 2 to OFF.
5 - You have completed the procedure
POINT G
- PrOGrAMMING rADIO CODEs fOr PEDEsTrIAN
OPENING
(UP TO 30 CODEs - ONLY fOr CrX MODELs)
You can only programme the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 3 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each,
for 10 seconds.
3 - Press the remote control button (normally channel B) within the 10 seconds
proscribed. If the remote control has been correctly programmed, the DL2 LED
(green) will flash once.
4 - The code programming time resets automatically so that you can programme
the next remote control.
5 - To finish programming, let 10 seconds pass and then press the PROG. button
briefly. The red DL1 LED will stop flashing.
6 - Reposition DIP 1 to OFF and DIP 3 to OFF.
N.B: If THE DL1 LED CONTINUEs TO fLAsH rAPIDLY, THIs MEANs
THAT DIP 1 Is sTILL POsITIONED TO ON AND ANY MANOEUVrE HAs
BEEN DELETED.
7 - You have completed the procedure.
PrOCEDUrE fOr DELETING ALL rADIO CODEs UsED ONLY fOr
COMPLETE OPENING
You can only delete the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 3 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each,
for 10 seconds.
3 - Press and hold the PROG button for 5 seconds. The green DL2 LED will flash
twice to confirm that the stored codes have been deleted.
4 - The red programming DL1 LED remains active and you can programme new
codes as shown above if required.
5 - Reposition DIP 1 to OFF and DIP 3 to OFF.
6 - You have completed the procedure.
HOW TO CHECK If THE MEMOrY Is fULL fOr rADIO CODEs UsED ONLY
fOr COMPLETE OPENING
You can only check the memory if the gate is closed.
1 - Position DIP 1 to ON and then DIP 3 to ON.
2 - The green DL2 LED will flash 6 times if the memory is full (30 codes have been
stored).
3 - After this, the DL1 programming LED will remain active for 10 seconds, so that
you can delete all codes if required.
4 - Reposition DIP 1 to OFF and DIP 3 to OFF.
5 - You have completed the procedure.
f
UNCTIONING Of CONTrOL ACCEssOrIEs
ATTENTION: ONLY IMPULsIVE COMMANDs HAVE TO BE
CONNECTED.
Make sure that any other type of command accessories (e.g. mass
detectors) used on the installation are set in the IMPULsIVE mode,
otherwise, the gate will be operated even without the protection of
the safety devices.
sTEP BY sTEP or AUTOMATIC commands
(K BUTT button, PED BUTT button, rADIO rEMOTE button)
DIP 6 - ON The K BUTT, the PED BUTT button, the RADIO REMOTE buttons
perform the cyclic command open-stop-close-open-stop-etc.
24
24

Publicidad

Tabla de contenido
loading

Tabla de contenido