5 - DISPLAY AND STATES OF THE CONTROL UNIT
By pressing the "DOWN" button it is possible to read on the display the following parameters.
DISPLAY
State showing (--, OP, CL, ...)
Maneuvers performed, e.g.:
02.0. (unit) / 001 (thousand), that is 1020 cycles.
5.1 - STATE OF THE CONTROL UNIT
DISPLAY
DESCRIPTION
--
Standby - Automation closed or after the switch on of the control unit.
OP
Opening phase.
CL
Closing phase.
SO
Automation stopped by the user during the opening.
SC
Automation stopped by the user during the closing.
HA
Automation stopped by an external event (photocells, stop).
oP
Automation opened without automatic reclosing.
PE
Automation opened on partial opening position without automatic reclosing
-tc
Automation opened with auto reclosing; in the last 10 seconds the dash will be replaced by the countdown.
Automation opened on partial opening position with auto reclosing; in the last 10 seconds the dash will be replaced by the
-tp
countdown.
5.2 - SIGNALLINGS DURING THE FUNCTIONING
DISPLAY
DESCRIPTION
RAD
Visualized during the learning of transmitters.
don
Visualized when a new transmitter is memorized or at the end of a reset
Fnd
Visualized when a key of a transmitter already memorized is stored.
CLR
Visualized when a trasmitter is erased.
LOP
Visualized during the learning of strokes to indicate that the control unit is opening the automation.
LCL
Visualized during the learning of strokes to indicate that the control unit is closing the automation.
L--
Visualized during the learning of strokes if there is an intervention of safety devices.
sEE
Visualized when the control unit waits for a transmitter signal, during the function of viewing of the memory location.
Not
Visualized when the transmitter is not stored on the memory, during the function of viewing of the memory location.
tout
Visualized when the control unit exits from the function of viewing of the memory location for inactivity.
SNd
Visualized during the first coupling with the Bluetooth device.
c --
Visualized when the control unit is connected to a Bluetooth device.
l --
Visualized when the Bluetooth device is disconnecting from the control unit.
power
Visualized when the power supply is not enough.
6-1622400
rev.03
ITA
07/09/2018
DESCRIPTION
Description of the control unit state. Refer to the STATES OF THE CONTROL
UNIT table for the description of the single states of functioning.
Maneuvers count: the display shows alternately the thousands (without
dots) and the units (with dots).
ENG
FRA
ESP
UP
DOWN
MENU
SS
7/20