7 - SETTING OF THE STROKE
NOTE - check with the advanced menu de.f.(chapter 9) if the selected motor type is correct, before carring out the learning.
At the first power up, it is necessary to carry out a learning of the stroke for the acquisition of the stroke length and the slowdowns.
After this procedure the installation is complete. To customize the automation, proceed as described in the chapter 8.
WARNING - Be sure that the limit switches are connected and correctly adjusted.
FIG. 6
Limit switch
intervention
E
C
B
7.1 - EASY SETTINGS OF THE STROKE
Be sure that the limit switches are connected and correctly adjusted.
Carry out a check of the menus and, if needed, customize the settings before
1.
the learning of the stroke.
The slowdowns will be those set in the menu, with the same percentage during
both opening and closing (LSI
Unlock the automation and move it to the middle of the stroke
2.
Press at the same time the "UP" and "MENU" buttons for at least 5 seconds
until the display shows LOP.
If the automation DOESN'T MOVE in opening, press the "DOWN" button to stop
3.
the learning. The display shows L--.
Press the "SS" button to restart the procedure: the automation moves in
4.
opening, at reduced speed, until it reaches the limit switch. In this phase the
display shows LOP.
Reached the opening limit switch, the automation moves automatically in
5.
closing, at running speed, until it reaches the closing limit switch. In this phase
the display shows LCL.
Reached the closing limit switch, the automation moves automatically in
6.
closing, at running speed, until it reaches the opening limit switch. In this
phase the display shows LOP.
Reached the opening limit switch, the automation moves in closing at running
7.
speed and with the slowdowns set into the menu LSI.
WARNING - in the event of a safety device intervention, the learning is stopped and will appear on the display
Press the "SS" button to start again the learning from the 4th point.
6-1622400
rev.03
D
A
P).
ITA
07/09/2018
A = area at running speed.
B = area at slowdown speed.
Limit switch
C = overstroke zone (the movement is at slowdown speed, if the
intervention
slowdown is enabled).
D = intervention zone of the amperometric sensor with
movement inversion (detects the obstacle).
E
E = intervention zone of the amperometric sensor with the stop
B
C
of the movement and the setting of the reached position as total
closing/opening position (resync area).
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
UP
MENU
SS
UP
UP
UP
ENG
FRA
ESP



DOWN
DOWN
DOWN
MENU
MENU
5 seconds
MENU
SS
SS
SS
DOWN
DOWN
DOWN
MENU
MENU
MENU

SS
SS
SS
DOWN
DOWN
DOWN
MENU
MENU
MENU
SS

SS
SS


DOWN
MENU

SS
DOWN
MENU

SS
L--
.
DOWN
DOWN
MENU
MENU
SS
SS












