420010329701 Maior P 300.1/400.1 AB
EN
3÷4 mm
Use only the suitable box wrench provided for this operation to remove the nozzle, taking care to not damage the elec-
trodes. Fit the new nozzle with the same care.
Note: Always check the position of electrodes after having replaced the nozzle (see illustration). A wrong position could
cause ignition troubles.
SUNTEC J 7 C 1000
1
SUNTEC
SUNTEC
SUNTEC
5
VERIFY:
- That piping system is perfectly sealed;
- That the use of hoses is avoided whenever is possible (use copper pipes preferably);
- That depression is not greater than 0,45 bar, to avoid pump's cavitation;
- That check valve is suitably designed for the duty;
The pump pressure is set at a value of 12 bar (13 bar Maior P 300.1) during the testing of burners. Before starting the
burner, bleed the air in the pump through the gauge port. Fill the piping with light-oil to facilitate the pump priming.
Start the burner and check the pump feeding pressure. In case the pump priming does not take place during the first
prepurging, with a consequent, subsequent lock-out of the burner, rearm the burner's lock-out to restart, by pushing
the button on the control box. If, after a successful pump priming, the burner locks-out after the prepurging, due to a
fuel pressure drop in the pump, rearm the burner's lock-out to restart the burner. Do never allow the pump working
without oil for more than three minutes. Note: before starting the burner, check that the return pipe is open. An even-
tual obstruction could damage the pump sealing device.

NOZZLE CLEANING AND REPLACEMENT

3÷4 mm
5÷6 mm

PRIMING AND ADJUSTMENT OF OIL PUMP

4
1
6
5
3
2
5÷6 mm
SUNTEC TA2C4
4
3
2
14
1 - INLET
2 - RETURN
3 - BLEED AND PRESSURE
GAUGE PORT
6
4 - VACUUM GAUGE PORT
5 - PRESSURE
ADJUSTMENT
6 - TO NOZZLE