WEG CFW-11 Guía De Instalación, Configuración Y Operación página 7

Ocultar thumbs Ver también para CFW-11:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1
KTY84-1
2
3
4
5
KTY84-2
6
7
8
KTY84-3
9
10 FC4
11 SEN4
KTY84-4
12 GND* 0 V reference for the sensors input
13 FC5
14 SEN5
KTY84-5
15
16
17
18
ATTENTION!
If sensor 1 is not used connect a wire between terminals XC14: 1 and
2. Proceed in the same way for sensor 2 interconnecting XC14: 4 and
5, for the sensor 3 interconnecting XC14: 7 and 8, for the sensor 4
interconnecting XC14: 10 and 11 and for the sensor 5 interconnecting
XC14: 13 and 14.
Temperature
Indications
(1)
Fault Levels
(1)
Alarm Levels
Note:
(1) See the numbers of the parameters, fault numbers, alarms and further details in the CFW-11
Programming Manual.
XC14
Function
FC1
Current source for Sensor 1
SEN1
Sensor 1 input
GND* 0 V reference for the sensors input
FC2
Current source for Sensor 2
SEN2
Sensor 2 input
GND* 0 V reference for the sensors input
FC3
Current source for Sensor 3
SEN3
Sensor 3 input
GND* 0 V reference for the sensors input
Current source for Sensor 4
Sensor 4 input
Current source for Sensor 5
Sensor 5 input
GND* 0 V reference for the sensors
Figure 6 - Connector XC14 – IOE-03
Range
Resolution
Accuracy
(1)
Table 3 - KTY84 inputs electrical specifications
Specifications
1.03 mA ± 2 %
0 to 1.77 Vdc; Rin = 1 MΩ
Isolated from the inverter's ground
1.03 mA ± 2 %
0 to 1.77 Vdc; Rin = 1 MΩ
Isolated from the inverter's ground
1.03 mA ± 2 %
0 to 1.77 Vdc; Rin = 1 MΩ
Isolated from the inverter's ground
1.03 mA ± 2 %
0 to 1.77 Vdc; Rin = 1 MΩ
Isolated from the inverter's ground
1.03 mA ± 2 %
0 to 1.77 Vdc; Rin = 1 MΩ
Isolated from the inverter's ground
-20 to + 200 °C
1 °C
± 10 °C
Adjustable by parameters
10 °C below the fault levels