Model ICBWS-30 Installation
Flush Inset Panels—Dual Installation
When installing two models ICBWS-30 or a model
ICBWS-30 and built-in unit side by side in a flush inset
application, you must decrease the width of the decorative
flush inset panels by 13 mm. Adjustments to the panel
offsets will also need to be made. These adjustments are
needed to achieve a proper fit and to ensure the panels do
not collide when closing. Panel dimensions in the chart
below have been adjusted to reflect the decrease in panel
dimensions.
IMPORTANT NOTE: If a filler strip is not used, dual installa-
tions can only be accomplished using two units with
opposite hinges.
Illustrations A–E provide panel offsets and reveals for
model ICBWS-30 in a flush inset application. Refer to the
chart below for reference to the illustrations. All reveals are
13 mm unless otherwise specified.
For additional information on panel reveals, visit the speci-
fication library section of our website, subzerotrade.com.
Do not exceed the flush inset decorative panel
dimensions. Exceeding dimensions could cause
damage to the panels and the Sub-Zero unit.
Panel Offsets
ALL REFRIGERATOR / ALL FREEZER
Doors (hinge) / Grille Sides
Doors (handle) Sides
Grille Top
Grille Bottom / Door Top
Door Bottom
TOP VIEW
DOOR / DRAWER / GRILLE
DOOR
BACKER
CABINETRY
SPACER
FLUSH INSET PANEL
8
mm
8
mm
13
mm
3
mm
16
mm
Illus. A
Illus. B
CABINETRY
13
mm
GRILLE
3
mm
8
GRILLE
mm
DOOR
SIDE VIEW
Illus. C
Illus. D
Illus.
DOOR /
DRAWER
A
B
C
8
D
mm
E
2
mm
SIDE VIEW
Illus. E
Side Panels
IMPORTANT NOTE: Side panels will need to be installed
TOP VIEW
before the unit is placed in its final position.
DUAL
TRIM
When installing a model ICBWS-30 with a custom side
panel, an accessory kit (7003407) is required. Classic
DOOR
stainless steel and white enamel side panels are available
through your Sub-Zero dealer. Refer to instructions
included with the side panel kit when installing these side
panels.
IMPORTANT NOTE: The use of side panels may change
6
mm
REVEAL
the width of your rough opening.
610 mm
8
mm
4
FRONT
mm
OF SIDE
PANEL
13
mm
2
mm
8
mm
SIDE VIEW
3 mm
ROUT TO
48 mm
25 mm
102 mm
OPTIONAL
67 mm
TOE KICK
CUT-OUT
Custom side panel dimensions.
CUSTOM SIDE PANEL INSTALLATION
The custom side panel will need to be a minimum of 610
mm deep and 13 mm thick. Refer to the custom side
panel dimensions illustration for additional specifications.
Routing will be necessary for the side panel to fit flush
against the side of the unit. Refer also to the routing detail
illustration.
IMPORTANT NOTE: The overall height on the side panel
will vary with the height of the grille being used. Make sure
you know your finished height before cutting any panels.
Install the brackets provided in the kit onto the side panel
in the locations shown in the illustration below. The front
brackets are meant to engage the mainframe and the back
brackets will wrap behind the unit when the panel is in
place. Screws are provided in the kit. If the provided
screws will not work for your installation, you will need to
provide the necessary screws to attach the brackets.
Place the panel at a 75° angle and engage the front
brackets into the mainframe. Swing the panel inward,
being sure that the front brackets engage the mainframe.
With the panel in position, attach the rear brackets to the
rear of the unit with the screws provided. Check to see
that the panel is secure. Refer to the illustration below.
2134
mm
25 mm
3 mm
13 mm
MAIN
FRAME
Side panel routing detail.
26
48 mm
FRONT
BRACKET
SIDE PANEL
MAIN
REAR
FRAME
BRACKET
SIDE PANEL
ROUTING
Side panel attachment
(top view).