Troubleshooting.

WARNING: Failure to disconnect power supply prior to
troubleshooting any wiring issues may result in serious
injury.
Problem: Fan fails to operate.
Solutions:
1. Check power to wall switch/wall control.
2. Verify that reverse switch is set completely in either direction.
3. Check to be sure code switches in remote control transmitter
and wall control are set properly.
4. Verify that receiver is wired properly.
5. Verify that wall control is wired properly.
6. Check to be sure fan is wired properly.
7. Check that red light on remote control transmitter turns on
when a button is pressed indicating that the battery is good.
8. Learning process between fan, remote control transmitter
and wall control may not have been successful and code was
not activated. Turn off power and repeat instructions in the last
paragraph of Section 10 (page 9).
Problem: Light kit not lighting.
Solutions:
1. Check wall switch to fan.
2. Check that bulbs are installed correctly.
3. Check that wires in canopy are wired properly.
4. Check to be sure code switches are set properly in remote
control transmitter and wall control.
5. Verify that molex connections in light kit fitter are connected
properly.
6. Learning process between receiver and transmitter may not
have been successful and code was not activated. Turn off
power and repeat instructions in the last paragraph of Section
10 (page 9).
7. Check to be sure that bulbs total no more than 190W.
Lamping light kit with bulb that totals more than 190W will cause the
wattage limiting device to interrupt the flow of electricity to the light
kit.]
Problem: Fan operates but light fails.
Solutions:
1. Check that bulbs are installed correctly.
2. Check to be sure wires in canopy are wired properly.
3. Verify that molex connections in light kit fitter are connected
properly.
4. Replace defective bulbs with same type of bulb.
5. Check to be sure that bulbs total no more than 190W.
Lamping light kit with bulb that totals more than 190W will cause the
wattage limiting device to interrupt the flow of electricity to the light
kit.]
Problem: Fan and light fail to operate with remote control.
Solutions:
1. Check battery power to remote control.
2. Check to be sure code switches are set properly in remote
control transmitter and wall control.
3. Learning process between fan, remote control transmitter
and wall control may not have been successful and code was
not activated. Turn off power and repeat instructions in the last
paragraph of Section 10 (page 9).
Problem: Fan wobbles.
Solutions:
1. Use the balancing kit provided in one of the hardware packs.
If no blade balancing kit is provided, please call Customer Support,
1-800-486-4892, to request one.
2. Check to be sure set screw(s) on motor housing yoke is (are)
tightened securely.
3. Check to be sure set screw on hanging ball is tightened
securely.

Warranty.

CRAFTMADE/ELLINGTON LIFETIME WARRANTY:
CRAFTMADE/ELLINGTON warrants this fan to the original
household purchaser for indoor use under the following
provisions:
1-YEAR WARRANTY: CRAFTMADE/ELLINGTON will replace
or repair any fan which has faulty performance due to a
defect in material or workmanship. Contact
Craftmade/Ellington Customer Service at 1-800-486-4892
to arrange for return of fan. Return fan, shipping prepaid, to
Craftmade/Ellington. We will repair or ship you a
replacement fan, and we will pay the return shipping cost.
5-YEAR WARRANTY: CRAFTMADE/ELLINGTON will repair or
replace at no charge to the original purchaser any fan
motor that fails to operate satisfactorily when failure
results from normal use.
RETURN FAN MOTOR ONLY, shipping prepaid, to
Craftmade/Ellington. We will repair or ship purchaser a
replacement motor and Craftmade/Ellington will pay the
return shipping cost.
6-YEAR to LIFETIME LIMITED WARRANTY:
CRAFTMADE/ELLINGTON will repair the fan, at no charge
for labor only to the original purchaser, if the fan motor
fails to operate satisfactorily when failure results from
normal use. Parts used in the repair will be billed to the
purchaser at prevailing prices at time of repair.
The purchaser shall be responsible for all costs incurred
in the removal, reinstallation and shipping of the product
for repairs.
[Note:
This warranty does not apply when damage from
mechanical, physical, electrical or water abuse results in
causing the malfunction. Deterioration of finishes or other
parts due to time or exposure to salt air is specifically
exempted under this warranty.
Neither Craftmade/Ellington nor the manufacturer will
assume any liability resulting from improper installation or
use of this product. In no case shall the company be liable
for any consequential damages for breach of this, or any
other warranty expressed or implied whatsoever. This
[Note:
limitation as to consequential damages shall not apply in
states where prohibited.

Parts Replacement.

For parts and information, please refer to
"Parts Inventory" on page 2.
Ellington Customer Support:
1-800-486-4892
www.craftmadebrands.com