Raise the safety shield, loosen the handle (N) and turn the depth regulating (O) dial so that the number
5 is aligned with the spindle support reference red notch (you should feel a click). Lock the lever (N).
Loosen the (F1) handle by one turn and pull the (F2) anatomic grip towards the operator. This releases
the clamp so that it can slide to the right or left. Release the anatomic grip and move the clamp manually.
The positioning device will lock the clamp in the clamp reference notch. When the clamp is in position
(Clamp A) tighten the (F1) handle.
Turn the (F) knob. to the left. Fit the key to be decoded into jaw A so that it lies flat against the clamp
with the tip up against Stop 2 (to do this the Stop 1 plate must be flipped left and downwards).
Secure the key by turning the (F) knob to the right.
N
Fig. 28
Pull the shield down and press START to begin decoding. If the protective shield is not closed, the
following message appears:
When the shield is lowered, the following message appears:
Press START to continue; first the display will show the message:
then:
at the end of the procedure the display will show the message (example):
24
O
C l o s e
s h i e l d !
C o n t i n u e ?
N o = S T O P
D E C O D I N G I N P R O G R E S S
S i d e : A
A x i s : 1
D E C O D I N G I N P R O G R E S S
S i d e : A
A x i s : 2
A x i s : 1 o f 2
S i d e s : A B
1 3 3 6 4 2
( 1 2 3 4 5 6 )
Copyright Silca 2006
F2
F1
Ye s = S TA R T
[ 6 ]
TRI-CODE H.S.