L5
Fig. 52
First the display will show:
then:
- if the calibration values read exceed the limits allowed (+/- 50 hundredths of a mm) (+/-0.0196")
calibration is not valid and the following message appears:
In this case the operation must be carefully repeated, paying great attention to all the steps, especially
positioning of the Z21 template.
- if the operation is successfully completed the display will show the difference between the theoretical
value and the one read (Delta).
Press [ENTER] to confirm the data and end the operation.
Press [STOP] to quit without saving.
Turn off the machine.
Replace the bottom panel, X axis protective cover and secure them with the screws provided.
Attention: after calibration of the 'Machine Zero Points', all the clamps must be calibrated.
56
L2
Y axis sensor
Z e r o d e t e c t i o n
i n p r o g r e s s !
E x c e e d e d s e t t i n g
t o l e r a n c e l i m i t !
X = + 5 3
Y = + 2 5 7
S e e o p e r a t i n g m a n u a l .
M a c h i n e z e r o p o i n t s
m e a s u r e m e n t s :
X = - 1 7
Y = - 3 2
N o = S T O P
Ye s = E N T E R
Copyright Silca 2006
TRI-CODE H.S.
0,1 / 0,4 mm (0.0039" / 0.0157")
measurement "Y"
L3