Step 3: Install the connection cap into the open end of the extension arm and
Step 4: Install conduit to the conduit connector located in the connection cap
Step 5: Connect the other end of the conduit to a second conduit connector
Installing the bulb
Step 1: Screw the bulb securely into socket.
Step 2: Back the bulb out one or two turns, then screw bulb back to insure
Installing the light sensor
Step 1: Make sure the screw in the center of receptacle (on top of fixture) is tight.
Step 2: Match up the largest prong on the light sensor (D) to the largest slot in
Step 3: Push sensor down into receptacle and twist clockwise 1/4 of a turn to
Step 4: Turn on the main power at the main fuse/breaker box.
Note: When power is initially turned on, the light may come on, even during
daylight. However, the light will turn off after two or three minutes and will only
come on at dusk thereafter. If artificial light sources (such as car headlights)
come in contact with the photo control, it may activate the photo control and
turn off the fixture. If this occurs, the fixture will have to cool down for
approximately 5 minutes before it will come on again.
11/1/05
2:24 PM
b. Connect black fixture wire to black supply wire (hot).
Secure with wire nut (not provided).
c. Connect white fixture wire to white supply wire (neutral).
Secure with wire nut (not provided).
d. Be careful to connect the wires correctly. Make sure no bare
strands of wire extend from the wire nut or other approve wire
connectors (not provided). After the connections are made,
the connections should be placed into the extension arm.
secure with (2) small screws (K). The screws will go through the notches
at the bottom of the extension arm.
just installed on the extension arm in Step 3.
and attach to the junction box. Make wiring connections inside of the
junction box.
proper position in socket.
the receptacle.
lock in place.
Call for customer service and/or missing or damaged parts (800-334-6871)