Pergola with 2 independent motors
2.3
1. MOTOR 1 CONFIGURATION
DIP4=OFF
DIP5=OFF
=
P1
CLOSE
2. MOTOR 2 CONFIGURATION
DIP4=ON
DIP5=OFF
=
P1
CLOSE
(
5 s)
+
P1
P2
Press P1 and P2 simultaneously
and hold for 5 s
=
P2
OPEN
If the direction is wrong, invert the motor wires.
=
P2
OPEN
If the direction is wrong, invert the motor wires.
...
L3 flashes
...
Continuous sound
M
24Vdc
Opening
M
24Vdc
Opening
6
Check that movement
stops when the limit switch
is reached (L1 ON)
L1
If it doesn't, change the
Closing
threshold as per PAR 2.4
(page 7) and repeat.
L1
Check that movement
stops when the limit switch
is reached (L2 ON)
L2
If it doesn't, change the
Closing
threshold as per PAR 2.4
(page 7) and repeat.
L2