TROUBLESHOOTING
IF THE FILL VALVE: • DOES NOT TURN ON
• WON'T TURN OFF
• WON'T REFILL TANK
REMOVE CAP AND CHECK FOR DEBRIS
A:
Turn off water supply, then flush toilet.
B:
With right hand push float up, grip and
hold shaft under float.
C:
With left hand twist cap and lever arm
counterclockwise to unlock cap. Let cap
hang on float cup.
D:
Hold empty cup upside down over un-
capped valve to prevent splashing.
E:
Turn water supply on and off a few times,
then leave it turned off.
F:
Replace valve cap.
• Place cap assembly on top of gray valve
body by aligning cap arm and adjustment
rod next to refill tube.
• Press down on top cap while rotating top &
arm clockwise to locked position.
For Kohler
toilets:
®
• If toilet isn't level and
leaning forward or
backward, losen or
tighten the back nut.
• If toilet isn't level and
leaning to the left or
right, losen or tighten
one of the two front nuts.
See Our Troubleshooting HOW-TO VIDEO
http://bit.ly/2yAdZn7
VIDEO
22
REPLACE FILL VALVE SEAL
A:
Remove cap (see page 22).
B:
Replace seal with a
Fluidmaster 242 Seal.
C:
Replace valve cap.
• Place cap assembly on top of gray valve body by
TURN
aligning cap arm and adjustment rod next to refill tube.
COUNTER-
CLOCKWISE
• Press down on top cap while rotating top & arm clockwise to locked position.
*
Always use genuine Fluidmaster parts when installing or repairing. Fluidmaster will not be
responsible or liable for use of non-Fluidmaster parts during installation or repair.
WATER LEVEL IN BOWL IS TOO LOW
A:
WATER FROM REFILL TUBE MUST
FLOW THROUGH OVERFLOW PIPE
Make sure the refill tube is supplying water down
overflow pipe. (Metal side out for refill clip)
B:
WATER LEVEL IN TANK MAY BE TOO LOW
1/2" below top of overflow pipe is recommended
(see page 17).
C:
FLAPPER MAY BE CLOSING TOO SOON
Give flapper chain approximately 1/2" of slack.
(small "j" shape)
D:
FILL VALVE DIAL MAY NEED TO BE
ADJUSTED
*
genuine
(see page 18).
Cap
Seal
Refill Tube
Overflow
Pipe
1/2"
Overflow
Pipe
23