Defender 6000 Indicators
To enable USB memory:
1.
After you insert a USB flash drive, long press the Menu button until you see
Short press the No button several times to navigate until you see
2.
3.
Short press the No button to navigate until you see
4.
The display flashes with
5.
Sub-menu Link to (
6.
Then the sub-menu appears with selections of RS232 (
EtHNEt
.
(
)
Choose the one you want and press the Yes button.
7.
The display shows
exit.
4.8.3 Alibi Memory (for i-DT61XWE model)
Note: This menu is only visible if the Alibi memory hardware option has been installed. See below for
installation instructions.
Alibi memory is used to store the weight history for reference. Each Alibi record contains the following:
•
ID
•
Gross /Net weight, tare weight and weight unit
•
Date and time
To check Alibi records, you need to install the ScaleMate software. Please contact an authorized dealer to
obtain the software
The maximum number of record is 262112.
When the memory is full and another record is stored, the first record will automatically be deleted. At this time
a warning message will appear, asking for the user's confirmation.
4.8.3.1 Enable Alibi
To enable:
1.
After you install the hardware, long press the Menu button until you see
Short press the No button several times to navigate until you see
2.
3.
Short press the No button to navigate until you see
4.
The display flashes with
5.
The display shows
button to exit.
4.8.3.2 Install Alibi
To install:
1.
Power off and unplug the terminal. Disconnect the terminal with a weighing pan if it is connected to one.
2.
Place the terminal down, and unscrew the screws marked in the following graphic.
ON
. Press the Yes button to enable.
LINK
) appears. Press the Yes button to enable.
END
. Press the Yes button. The display shows the next menu. Press the Exit button to
ON
. Press the Yes button to enable Alibi.
END
. Press the Yes button. The display shows the next menu
mM.e.mM.O
USb
. Press the Yes button.
rS232
), 2nd Serial (
C.A.L
mM.e.mM.O
ALIBI
. Press the Yes button.
C.A.L
.
. Press the Yes button.
2.SErIA
) and Ethernet
.
. Press the Yes button.
L.I.b
. Press the Exit
EN-41