TERMINAL BOARD CONNECTIONS
1 - 2
FS1 - FS2:
in the SPIN12Q motor and protected by a fuse on the 230 Vac power supply;
3 - 4
motor 1 (M1) supply output 18 Vdc max. 50 W;
5 - 6
motor 2 (M2) supply output 18 Vdc max. 50 W;
7 - 8
433,92 MHz built-in RX aerial input; 7 = Signal 8 = Earth;
9 - 11
Input for open/close push button (normally-open contact): for usage, see the func-
tions of dip switches 2-4; 9 = Open/close; 11 = Common;
10 -11
Stop push button NC (normally closed) contact. After a stoppage, the system always
starts again only after receiving a command from the On button or radio transmitter.
10 = Stop; 11 = Common;
11 - 12
Resistive sensitive edge input (DIP 5=ON); sensitive edge input – fixed edge (DIP
5=OFF); 11 = Common; 12 = Sensitive edge.
If neither the resistive sensitive edge nor the fixed edge are used, set DIP 5 to OFF
and short circuit terminals 11 and 12;
13 - 14
Output for auxiliary courtesy light 18 Vcc max 15 W;
TIVE);
15 - 16
18 Vdc max. 20W output for flashing light supply (15 = POSITIVE - 16 = NEGATIVE),
flashing signal supplied by the control unit, rapid for closing, slow for opening;
17 - 18
auxiliary circuits output 18 Vdc max. 15 W (17 = POSITIVE - 18 = NEGATIVE) for
photocells, receivers, etc...;
M3
PIN1 GND - Negative (BLUE)
PIN2 +5V - Positive (BROWN)
PIN3 ENC - ENCODER Signal (WHITE)
M4
PIN1 Common
PIN2 Input for
PIN3 Input for STOP push button
PIN4 Common
IMPORTANT:
do not connect auxiliary relays
endangering the correct functioning of the control unit;
do not connect switching feeders or similar apparatus close to the control
unit that may be a source of disturbance.
16
board supply input 13.5 Vac – Powered by the toroidal transformer housed
STEP BY STEP push button
(terminals no. 17 and no. 18)
K996M
(13 = POSITIVE - 14 = NEGA-
so as to avoid