28
The character with the 00 code moves the cursor forward by one position.
CAUTION! : If the cursor is on the other side of the first character of the message and you press the ESC key
to return to the main menu, the message is cut off at the point which corresponds to the position of the
cursor; therefore before quitting, make sure that the cursor is moved to the end of the message.
It is advisable to prepare the message on a piece of paper using the codes in the table (spaces included) and
then enter it in the machine.
Command 96 Enter user message 2 (max 63 characters):
This command makes it possible to enable and enter the second of the two messages which can be edited
by the manager. This message is displayed in STAND-BY when the payment system can not deliver the
change. To enter this message the same rules apply as those for the preceeding command.
Command 99 View error events:
This command displays the last 20 error events; to go from one display to another press the ENTER key. At
the end of the display, the system asks the user to confirm the clearing of all the data. Press ENTER to
E
confirm or ESC to leave the records as they are.
N
ERROR
G
CODE
L
01
Number selection code
I
02
Number selection code
S
03
H
04
05
Number selection code
05
06
07
08
09
Number selection code
09
10
10
11
11
12
13
14
16
17
18
20
21
30
31
39
41
42
51
55
32÷38
91
Number selection code
(*) Key:
33 = Photocells
38 = Spirali Master
81 = Microwave oven.
FAS INTERNATIONAL S.p.A. Via Lago di Vico, 60 SCHIO (VI) – tel. +39 0445 502011 – fax +39 0445 502010 - e-mail: info@fas.it
SUB-CODE
Motor blocked (the spiral does not
The spiral does not complete the
(*) 81
Oven rotation motor hardware protection device tripped
(*) 81
Oven rotation motor position timeout
Motor disconnected
(*) 81
Product turnover rod motor disconnected
(*) 81
Oven cover timeout (the cover will not close)
(*) 81
Oven cover timeout (the cover will not open)
(*) 81
Motor rotation error
Possible microswitch defect or spiral motor wiring defect
(*) 81
Motor rotation error
(*) 38
Internal temperature feeler faulty
(*) 81
Motor rotation error
(*) 38
Evaporator probe faulty
(*) 81
Microwave oven cavity rotation motor current overload
(*) 81
Anti-spark sensor tripped
(*) 81
Product turnover rod motor rotation error
(*) 81
The magnetron does not go on
(*) 33 - 38
Error communication with peripheral (a board for
(*) 38
Communication break during sale cycle without credit collection
(*) 38
Communication break during sale cycle with credit collection
(*) 38
Opening door lock error
(*) 38
Closing door lock error
(*) 38
Fridge safety has intervened
(*) 38
Photocell test error .
(*) 38
photocell safety
(*) 81
The product to heat is not in the cavity
(*) 81
Product trapped inside the cavity
Interruption of peripheral connection at the beginning of the sale
(*) 38
cycle.
/
Payment system out of service.
(*) 38
Photocell calibration error
Selections not reset.
JUST NOW – Issue 00
FAILURE
rotate)
rotation
the electric panel)