TP-250 Utility Pump
1. This pump has been designed to attach to a
standard garden hose. Thread the female end of
the garden hose to the discharge on the pump.
2. To reduce leakage between the pump and the
hose, place a hose washer (not included) on the
garden hose before use to the pump.
3. For best pump performance, unwind the hose
before starting the pump. This will help remove
any kinks or binds in the hose and allow the unit
to pump with less restriction.
4. Place pump on a hard surface in the water.
Do not set the pump directly on mud or sand
surfaces. This will cause the inlet screen to clog.
Do not place pump directly on
clay, gravel, or any loose or sandy surfaces. These
surfaces contain small stones or sand that may clog
or damage the pump. This could result in pump failure
causing flooding and property damage.
5. The water level must be at least 1/2 inch for the
pump to operate. Water levels less than 1/2 inch
will not allow the impeller to contact water and
no water will be pumped.
6. Inspect the power cord and plug for damage. If
the plug is missing the grounding prong or the
cord is damaged, do not use the pump until the
cord has been replaced.
• Never cut off grounding prong or use an adapter.
7. Plug the power cord into a grounded 120-volt AC
power outlet. Make sure the electrical outlet is
grounded and is rated for at least 15 amps. The
pump will start operating as soon as the power
cord is plugged into the power outlet.
8. The pump will remove water down to 1/8 inch of
the surface the pump was placed on.
9. The pump should be unplugged once the water
has reached the 1/8 inch height, or pump will run
dry.
Do not allow pump to run dry.
The shaft seal depends on water for lubrication.
Operating the pump without water will damage the
shaft seal and cause pump failure.
4
When routing electrical cord protect cord from sharp
objects, hot surfaces, oils, and chemicals. Do not kink
cord; replace any damaged cord immediately.
Maintenance Instructions
electrical supply or unplug the pump before
attempting to install, service, relocate, or perform
any maintenance. If the power source is out of
sight, lock and tag in the open (OFF) position to
prevent unexpected power application. Failure to
do so could result in fatal electrical shock. Only
a qualified technician should repair this unit.
Improper repair could result in fatal electrical shock.
1. Keep pump inlet clean and free of all foreign
objects. Inspect inlet at beginning of each use.
2. The motor housing is completely sealed and
requires no service. Disassembly of the motor
housing or alteration of the power cord could
result in fatal electrical shock.
Ridge Tool Company
Always disconnect the