Direct RGB
Direct Red
Direct Red-Blue
Direct RGB,
Indirect Monochrome
Direct Green-Blue,
Indirect RGB
Table 4: Examples of settings of dip-switches S4 in ROLLING mode to choose colours belonging to rolling set
To set rolling speed, locate S4 dip-switches and set dip-switches 9-10 as in following Table 5.
To set SWITCH-ON mode (see also below 9.3), locate S5 dip-switch and set as per Table 6.
SWITCH-ON mode
Safety: system remains switched-off after a loss and return of the electric net
Wall switch: system restore last stored scenery after a loss and return of the electric net
Table 6: Setting of dip-switches S5 in ROLLING mode to choose SWITCH-ON mode after a loss and return of electric net.
NB: please note that the meaning of these modes is:
-
Safety: to let the system remain safely switched off after a loss and return of electric net
-
Wall switch: to be able to switch on and off the system by means a wall-switch or timer-switch. Last stored scenery will be
restored when wall switch or timer-switch is re-activated.
S4-8
S4-7
Indirect
Indirect
Monochr.
Blue
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
Speed
Very slow
Slow
Medium
Fast
Table 5: Settings of dip-switches S4 in ROLLING mode to choose rolling speed
DIP-switches S4
S4-6
S4-5
S4-4
Indirect
Indirect
Direct
Green
Red
Monochr.
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
DIP-switches S4
S4-10
S4-9
OFF
OFF
OFF
ON
ON
OFF
ON
ON
S4-3
S4-2
S4-1
Direct
Direct
Direct
Blue
Green
Red
ON
ON
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
OFF
ON
ON
ON
DIP-switches S5
S5-1
S5-2
OFF
OFF
ON
OFF
22