Fan operates but there is
no coolant flow.
Pump operates, but fan
does not.
Cooler trips outlet circuit
breaker.

Electromagnetic Compatibility (EMC)

This machine has been designed in accordance with all relevant directives and standards. However, it may still generate
electromagnetic disturbances that can affect other systems like telecommunications (telephone, radio, and television) or
other safety systems. These disturbances can cause safety problems in the affected systems. Read and understand
this section to eliminate or reduce the amount of electromagnetic disturbance generated by this machine.
This machine has been designed to operate in an industrial area. To operate in a domestic area it is
necessary to observe particular precautions to eliminate possible electromagnetic disturbances. The
operator must install and operate this equipment as described in this manual. If any electromagnetic
disturbances are detected the operator must put in place corrective actions to eliminate these disturbances
with, if necessary, assistance from Lincoln Electric.
Before installing the machine, the operator must check the work area for any devices that may malfunction because of
electromagnetic disturbances. Consider the following.
Input and output cables, control cables, and telephone cables that are in or adjacent to the work area and the
machine.
Radio and/or television transmitters and receivers. Computers or computer controlled equipment.
Safety and control equipment for industrial processes. Equipment for calibration and measurement.
Personal medical devices like pacemakers and hearing aids.
Check the electromagnetic immunity for equipment operating in or near the work area. The operator must be sure
that all equipment in the area is compatible. This may require additional protection measures.
The dimensions of the work area to consider will depend on the construction of the area and other activities that are
taking place.
Consider the following guidelines to reduce electromagnetic emissions from the machine.
Connect the machine to the input supply according to this manual. If disturbances occur if may be necessary to take
additional precautions such as filtering the input supply.
The output cables should be kept as short as possible and should be positioned together. If possible connect the
work piece to ground in order to reduce the electromagnetic emissions. The operator must check that connecting
the work piece to ground does not cause problems or unsafe operating conditions for personnel and equipment.
Shielding of cables in the work area can reduce electromagnetic emissions. This may be necessary for special
applications.

Technical Specifications

Input Voltage
400 V ± 10%
single phase
Flow range
Reservoir size
Coolant requirement:
Do not use prepackaged welding industry coolants. These
coolants may contain oil-based substances which attack
the plastic components in the pump.
Height
245 mm
Operating Temperature
–10°C to +40°C
English
Pump failure.
Pump seized.
Fan blade contacting heat exchanger.
Fan motor failure.
Circuit overloaded.
Cooler electrical component failure.
RATED OUTPUT AT 40°C
MIG
TIG
Open flow
PHYSICAL DIMENSIONS
Width
305 mm
Replace pump.
Replace pump.
Replace fan.
Replace fan.
Check outlet circuit breaker.
Replace suppressor assembly and rectifier
bridge inside of cooler.
INPUT
Rated current
0,8 A
with torch 4,5m: 1,7 ÷ 1,8 l/min
with torch 3,8m: 1,3 ÷ 1,4 l/min
Recommended coolant for COOLARC-45: Acorox
Water or water and pure ethylene glycol mixture can be
used interchangeably.
The glycol % must not exceed 30%.
Length
710 mm
5
Frequency
50/60 Hz
0,5 to 3,3 l/min
3,3 l/min
6 l
Weight
22 Kg
Storage Temperature
-25°C to +55°C