Technical specifications

Technical characteristics

Voltage supply
Amperage
Maximum output
Temperature control range
Minimum water pressure
Maximum water pressure
Minimum flow rate
Maximum flow rate
Weight (without water)
The unit will work at lower supply voltages but the following changes will apply:
Maximum output
Maximum power
(refer to Fig. 8)
Table 5
3

Regulations

Any local by-laws and regulations pertaining to installation and
use of electric water heating appliances must be observed.
Please refer to the laws that should be attended in your
country.
The electrical installation must conform to current National
Electrical Codes.
As per the Canadian Electrical Code, C22.1-02 Section 26-
744, an auxiliary terminal block must be fitted to the unit
before connecting to the electrical supply.
A green terminal (or wire connection marked "G", "GR",
"GROUND" or "GROUNDING") is provided within the
control box. Aditional Canadian safety instructions, to
reduce the risk of electrical shock, connect this terminal or
connector to the grounding terminal of the electrical
service of supply panel with a continuous copper wire in
accordance with the Canadian Electrical Code, Part I.
In Canada, this product shall be protected by a Class A
ground fault circuit interrupter.
In the Commonwealth of Massachusetts a licensed
plumber or electrician must perform the installation.
(Approval number: P1-09-25).
In the Commonwealth of Massachusetts a pressure relief
valve shall be installed on the cold water side by a licensed
plumber. (MGL 142 Section 19, Approval number P1-09-
25).
Tronic 5000C
Units
WH36
V
1 X 240
A
3 x 60A (Canada 180A)
kW
36.0kW
95 °F to 131 °F
psi
14.5psi
psi
150psi
gal/min
0.6 US gal / min
(refer to Fig. 8)
lbs
26.5 lbs
30.2kW at 220V
27.0kW at 208V
84% of maximum at 220V
75% of maximum at 208V
The unit must be wired by a qualified electrician, in
accordance with the current version of the National
Electrical Code US) or Canadian Electric Code (Canada).
When the heater is not within sight of the electrical circuit
breakers, a circuit breaker lockout or additional local
means of disconnect for all non-grounded conductors must
be provided that is within sight of the appliance. (Ref NEC
422.31.).
The power cable size and the installation must be in
accordance with the Canadian Electrical Code, C22.1-02.
WARNING:
California Proposition 65 lists chemical
substances known to the state to cause
cancer, birth defects, death, serious illness
or other reproductive harm. This product
may contain such substances, be their
origin from fuel combustion (gas, oil) or
components of the product itself.