Step 3: Check the receiver settings
If still no reception can be obtained, check the receiver settings once again:
There is a red LED on the multi-switch, which flashes briefly when the switch-over
command is received from the receiver. If the receiver then receives no signal from the
multi-switch, it generally sends out a command every 1 to 3 seconds. The red LED then
flashes on each occasion. If the receiver does not repeat the commands automatically,
it must be "zapped" manually.
Problem
Continuous message
"Poor or no signal"
Short message:
"Poor or no signal"
or image breaks in at
regular intervals
Electronic equipment is not household waste - in accordance with directive 2002/96/
EC OF THE EUROPEAN PARLIAMENT AND THE COUNCIL dated 27
on used electrical and electronic equipment, it must be disposed of properly. At the
end of its service life, take this device for disposal at a
designated public collection point.
www.kathrein.com
KATHREIN-Werke KG • Anton-Kathrein-Straße 1 - 3 • P.O. Box 100 444 • 83004 Rosenheim • Germany • Phone +49 8031 184-0 • Fax +49 8031 184-385
Red
Possible cause
LED
Receiver not in
single cable mode
Off
Wrong PIN code
Flas-
UB and frequency
hing
do not match
Another subscriber
Flas-
is accessing the
hing
same UB to
936.4862/a/VMPT/0715/GB - Subject to technical changes!
Solution
Check the tuner settings
Check the PIN code number
or deactivate the PIN feature
Adjust the tuner settings.
The UBs and their associated frequen-
cies are listed on the multi-switch or under
"Technical Data"
(Caution: The SCR number is one
less than the UB number)
Check the menu settings of all connected
receivers. Check unique assignment
of frequencies and UBs.
January 2003
th