Overview
Pos.
Description
X11
External 24 V supply
X12
4 digital outputs
1 digital input
Nameplate, retractable
Setting of mains voltage/brake chopper threshold
Upper cap
Cable fixation for L1 ... L3, , also serves as a lifting aid, at the top and bottom, can be removed
Cable fixation for +UG/-UG, can be mounted at the top and bottom
Module front with removable cable opening covers
Cable connection +UG/-UG (also specified as part of X111 or X112)
Nameplate 2
Pos.
Description (connections)
X111
Mains (supply from above, e.g. through top-mounted filter)
DC-bus voltage (compatible to 9300 series)
X112
Mains (supply from below, e.g. through side-mounted filter)
External brake resistor
DC bus
X109
DC busbar +
X110
DC busbar -
The LED display enables fast indication of several operating states.
LED
Labelling
-
OVERHEAT
MAINS
BRCHOP FAIL
24 V
BRCHOP ON
SSP94LED21
Pos.
Symbol
© 2007 Lenze Drive Systems GmbH, Hans-Lenze-Straße 1, D-31855 Aerzen
No part of this documentation may be reproduced or made accessible to third parties without written consent by Lenze Drive
Systems GmbH.
All information given in this documentation has been selected carefully and complies with the hardware and software described.
Nevertheless, discrepancies cannot be ruled out. We do not take any responsibility or liability for any damage that may occur.
Necessary corrections will be included in subsequent editions.
30
Colour
Description
-
-
Red
Overtemperature
Green
Mains voltage OK
Red
Short circuit on brake chopper
Green
24 V supply voltage OK
Yellow
Brake chopper active
Description
Long discharge time: All power terminals carry hazardous voltages for at
least 3 minutes after mains disconnection!
High discharge current: Fixed installation and PE connection to EN 61800-5-1
required!
Electrostatic sensitive devices: Before working on the device, personnel must
ensure that they are free of electrostatic charge!