INDICATIONS OF DISPLAY
updating both the electrical input sensors leaf 2 (during programming)
updating both the electrical input sensors leaf 1 and leaf 2 (during programming)
Opening plus compensation electrical input monitor 1
Opening plus compensation electrical input monitor 2
Closing plus compensation electrical input monitor 1
Closing plus compensation electrical input monitor 2
Battery mode (charged battery)
Battery mode (flat battery)
Block caused by a flat battery
MANUAL OPERATION MODE
This can be used to close the door (or open it) under the direct control of the operator (in this mode the security devices
FTC_I, FTC_S and TB only intervene when they are in alarm). The aim of this command is to make installation easier and
to allow you to have the door completely closed before starting the programming procedure. In this mode the LED "L3"
(marked "UPL") will remain lit. The "manual mode" can also be used while working off battery power; the motors are
supplied with the maximum voltage (turnover speed) whether or not deceleration has been programmed. The FTC_I (only
in the closing direction regardless of the selection made at step "C" during programming ) and FTC_S safety devices are
managed in the same way as for the travel limits and the electrical input sensors.
• Closing manoeuvre
This is obtained by pressing the button "SEL". The motor will block in the closing direction due to:
- releasing the "SEL" button (takes you out of the "manual operation mode").
- activating the blocking button "TB": to move the door again you must first release the "SEL" button and then
press it again.
- activating the closing direction travel limit (if installed): pressing the "SEL" button will not cause the door to close,
but it will switch the night light on.
• Opening manoeuvre
This is obtained by pressing the button "SEL", and then the "PROG" button straight away. The motor will block
in the opening direction due to:
- releasing both buttons (takes you out of the "manual operation mode").
- activating the blocking button "TB": to move the door again you must first release both buttons and then
press them again.
- activating the opening direction travel limit.
• Travel direction inversion
If the door is closing: to enable an opening manoeuvre: press the "PROG" button
If the door is opening: to enable a closing manoeuvre: release the "PROG" button
lig
• Night
ht
The night light remains on all the time while in the "manual operation mode"; it also lights up when an opening or closing
command is given but the travel limit blocks the command.
18