Fault Finding Chart - Lowara FC Serie Instrucciones De Instalacion Y Uso

Electrobombas centrífugas
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 26
en

8. Fault finding chart

PROBLEM
1. Pump does not start
2. Pump does not de-
liver
3. Insufficient delivery
4. Pump stops after a
short interval
5. The pump vibrates
and is too noisy
16
PROBABLE CAUSE
A) No power supply
B) Automatic switch tripped or blown
fuses
C) Overload protection
D) Impeller jammed
A) There is air in the system and in
the pump body
A) Incorrect direction of rotation
B) Pump or pipes obstructed
C) Pump runs beyond rated capacity
A) Overload protection
The pump does not rotate freely
Liquid is too viscous
A) Worn ball bearings
B) The pump is cavitating
C) Foreign matter inside the pump
POSSIBLE REMEDIES
A) Supply electrical power
B) Re-set the switch and replace the
fuse
C) Re-set the protection
D) See point 6.2
A) Bleed the system and prime the
pump (see point 6.2)
A) See point 6.1
B) Disassemble and/or clean
C) Partially close the delivery gate
valve
A) The pump does not rotate freely
Liquid is too viscous
A) Replace bearings
B) See paragraph 6.2
C) Disassemble and/or clean

Publicidad

Tabla de contenido
loading

Tabla de contenido