8.2

Description of LEDs / buttons

See Figure 12
6
12
4
5
7
8
11
10
1 - 2
3
9

INTERFACE OPERATIVITY

9.1

Passage from Monitor to SETUP mode and vice-versa

To pass from Monitor mode to SETUP mode, hold down the buttons "-" (Figure 12, 1) and "Reset/Select" (Figure 12, 3) simultaneously for at
least 3 seconds. To pass from SETUP mode to Monitor mode, hold down the buttons "–" (Figure 12, 2) and "Reset/Select" (Figure 12, 3)
simultaneously for at least 3 seconds or wait for 1 minute without touching any button on the interface. When switched on, the COM BOX is in
Monitor mode by default. SETUP mode is indicated by the alternate blinking of the ENGINE STATUS and ALARM LED.
9.2

Monitor mode

Motor status (Fig 12, 4)
If the green "Motor Status" LED is lit, the motor is powered.
Alarm reading (Fig 12, 5)
If the "Alarm" LED is lit, it indicates that an alarm has been activated. The lighting of the RED ANTICYCLING or DRYRUN LED indicates which
alarm is active.
MANUAL MODE function (fig.12, 7)
The active "MANUAL" mode is indicated by the lit LED. To activate/deactivate this mode, see the chapter "SETUP Mode".
PLC connection (Fig 12, 8)
If the BLUE LED is lit, the PLC connection is active or the COM BOX is available for connection to a pump.
If the LED is lit with a steady light, the connection is active.
If the LED is flashing slowly (1 second ON; 1 second OFF) it indicates that the connection is not active, but COM BOX is associated with the
pump.
LED
Function
CUT-IN (SETUP mode)
SYSTEM PRESSURE
(MONITOR mode)
ENABLE/DISABLE
MOTOR STATUS
MANUAL MODE
ANTI DRYRUN
ANTI-CYCLING
-
-
RESET/SELECT
ENGLISH
The lit LED indicates the CUT-IN value (SETUP mode)
The LED bar indicates the system pressure (MONITOR
System status: led on indicates pump enabled, led flashing
ALARM
Indicates the communication status between pump and
PLC
Indicates that there is an ANTICYCLING alarm (MONITOR
mode) and/or that the ANTICYCLING activated status has
+ / -
Table2
21
Explanation
mode
indicates pump disabled.
Indicates that the pump is running
Indicates that there is a general alarm
Indicates manual operation
COM BOX
Indicates that there is a DRY RUN alarm
been detected