AIR SUPPLY TO APPLIANCE.
A room air entry opening or openings is or are needed. These must have a
total free area of at Ieast 550mm
a flue stabiliser is used the total free area should be incraesed by 300mm
for each kW of rated output.
LIGHTING AND OPERATING WITH WOOD
Place tightly rolled paper, wond kindling or firelighters together with some
small logs on the oscillating grate. Light the paper or firelighters. Open air
wash control n° 1, Ieave the stove door slightly ajar, open thermostat no.2.
-
1
Open the direct draught damper (3) to warm the chimney (pull the handle to the right)
After about 10 minutes (more time for poorly drawing chimneys) when combustion is well
under way, close the direct draught damper (3) (push the handle to the left) close the
thermostat n° 2. Adjust the tempo of the fire by means of the air wash control n° 1.
OPERATION WITH WOOD
The air wash control n° 1 enables the tempo of the stove to be adjusted by the size of
the intake opening. With the tool provided the control can be adjusted to the heat output
required.
OVER NIGHT BURNING
If you fill your appliance with wood and close all air supplies, you will, no
doubt, easily achieve overnight burning though it is probable that the glass
47