Electrical Requirements

Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on
the following pages. The receptacle may also be located
in an adjacent cabinet within reach of the power cord. A
separate circuit, servicing only this appliance is required. A
ground fault circuit interrupter (GFCI) is not recommended
and may cause interruption of operation. Refer to the illus-
tration below for minimum power cord plug clearance.
EL EC T R IC A L R EQ UI R EM ENT S
Electrical Supply
Service
Receptacle
Power Cord
NEMA
PLUG
GROUNDED
NEMA RECEPTACLE
NEMA 6-20R receptacle
4 | Wolf Customer Care 800.222.7820
grounded, 240/208 VAC, 60 Hz
15 amp dedicated circuit
NEMA 6-20R grounding type
6'
(1.8 m)
1"
(25)
MINIMUM
CORD
CLEARANCE
Power cord clearance
WARNING
ELECTRICAL SHOCK HAZARD: Plug into a grounded
3-prong outlet. Do not remove the ground prong. Do
not use an adapter. Failure to follow these instructions
can result in electric shock, fire, or death.
RATING PLATE
Rating plate location