PLEASANT HEARTH ZERO CLEARANCE FIREBOXES
BLOWER INSTALLATION
If you are installing the forced air kit on PHZC32C, PHZC36C, and PHZC42C models, see the installation instructions provided with the kit
for electrical wiring requirements, or the blower installation section. The firebox must be connected to main power supply at time of
firebox installation. The blower should be installed prior to the installation of the vent-free heater but can be installed after installation if the
electrical connections have already been installed. The electrical connections must be made before the firebox is framed and enclosed in
the finished walls.
WARNING!
Electrical connections should only be performed by a quali-
fied, licensed electrician, main power must be off when
connecting to
main electrical power supply or performing service.
The blower when installed, must be electrically grounded
in accordance with local codes or in the absence of local
codes, with the National Electrical Code ANSI/NFPA 70.
Blower Installation Instructions:
1. Lower the bottom grill assembly and remove the
blower mounting bracket attached to the inner back
wall of the firebox with a #2 phillips screw driver.
2. Attach the blower to the bracket with the (4) sheet
metal screws included int he blower kit as shown in
Figure 15.
3. Re-install the bracket insuring the blower outlet is
pointed upward.
4. Plug in the cord to the properly grounded 3-prong
receptacle.
(4) Sheet Metal Screws
Included in Blower Kit
Optional ZCB100 Blower Kit
(4) #8 Sheet Metal Screws
WARNING!
Never use an extension cord to power the blower.
POWER CORD / CABLE DE ENERGIA
B
A
Electrical Box
Figure 15 - Optional Blower Installation
2
SI SE DEBE REEMPLAZAR UN CABLEADO
IF ANY ORIGINAL WIRING SUPPLIED
WITH THIS HEATER MUST BE REPLACED,
ORIGINAL PROVIEIDO CON EL CALENTADOR,
DEBE SER CABLE TIPO AWG 105C O SU
IT MUST BE TYPE AWG 105C WIRE OR ITS
EQUIVALENT EXCEPT AS INDICATED.
EQUIVALENTE, EXCEPTO SI SE INDICA DE
OTRA MANERA.
2
Fig.
- Optional Blower Installation
3
WIRING DIAGRAM
BLACK / NEGRO
GREEN / VERDE
MOTOR / MOTOR
EARTH (SHELL)
TIERRA (CUBIERTA)
WHITE / BLANCO
DRAWN
DanDowning
2/14/2018
CHECKED
6440 W Howard St., Niles, IL 60714
APPROVED
TITLE
WIRING DIAGRAM
MATERIAL
ZCF FIREBOX BLOWER
TOLERANCES
X.XXX = +/- 0.005"
SIZE
X.XX
= +/- 0.010"
A
X.X
= +/-0.100"
SCALE
ANGLES = +/- 2 Deg.
Lower Grill Assembly
Blower Mounting Bracket
1
GHP Group Inc.
DWG NO
REV
ZCF-5060
1

Publicidad

Tabla de contenido
loading

Tabla de contenido