Ingersoll- - Rand No. 50
Always use of an air line lubricator. We recommend the
following Filter- - Regulator- - Lubricator Unit (FRL):
Inside USA use FRL unit # C28- - 04- - FKG0- - 28
Outside USA use FRL unit # C28- - C4- - FKG0
Model
I.D.
232TGSL
LUBRICATION
Ingersoll- - Rand No. 100
INSTALLATION
Main Line(s) Inner Ø
to be 3X Size of
Air Tool's Inlet Ø
To Air
System
To Air
Tool
L
Emergency
Shut--Off
Valve
Lubricator
Regulator
FRL
Drain Regularly
SPECIFICATIONS
Handle
Type
pistol
After each eight hours of operation, if an airline
lubricator is not used, remove the Oil Chamber Plug (17)
and fill the oil chamber with Ingersoll- - Rand No. 50 Oil.
After each eight hours of operation, or as experience
indicates, inject about 4 cc of the Ingersoll- - Rand No. 100
Grease into the Grease Fitting (16).
Branch Line(s) Inner Ø
to be 2X Size of
Air Tool's Inlet Ø
R
F
Filter
Compressor
(Dwg. TPD905- -2)
Drive
inches
1/2 sq.
3
Recommended Torque Range
ftSlb (NSm)
40- - 400 (64- - 542)